Installation
146
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
If the communication server cannot find a DHCP server within 90 seconds, it deacti-
vates the DHCP mode and is then accessible via the standard IP address (see
Tab. 74
) with a direct connection.
Note:
DHCP is deactivated only temporarily and is reactivated after a subse-
quent restart.
Cable types
The Ethernet switch on the communications server features Auto MDI/MDIX. With
the automatic detection straight or crossover LAN cables can be used for all con-
nection types.
Configuration
The Ethernet interfaces routed to the front panel can be configured individually in
the
IP addressing
(
=9g
) view. In addition to Auto modes, manual settings are also
possible for
Speed
and
MDI type
.
Status LED
The status of the Ethernet interface LAN1 is indicated on the LED display panel (see
"LED display", page 204
).
Cable Requirements
Use commercial Cat. 5 cable, or choose a cable type with the following characteris-
tics:
Tab. 75
Requirements for an Ethernet cable
See also:
For more information about the Ethernet interface on the application
card, see the CPU2-S application card installation manual.
Core pairs
cores
2
2 (short distances also 1
4)
Stranded
yes
Wire diameter, core
0.4...0.6 mm
Screening
yes
Category
Cat. 5 minimum