Installation
120
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
• Maximum line length for a wire diameter of 0,5 mm: 820 m
• Maximum line length for a wire diameter of 0,6 mm: 1170 m
Example 3:
Evaluation of an existing line installation
Line diameter: 0.5 mm
Loop resistance: 120
Fig. 43
indicates:
• Line length: 660 m
• Power available: 2120 mW
Cable Requirements
Tab. 53
Requirements for an DSI bus cable
Installation rules
• If an Aastra DECT radio unit is used, do not connect any other system phone to
the same DSI bus.
• Do not use any terminating resistors at the bus extremity.
• Avoid using different cable cross-sections on the same bus
• Use the supplied cables for connecting the system phones
• Cabling of AD2 terminals is restricted to pairs of a separate dedicated cable(s).
1)
.
Core pairs
cores
1
2 o 1
4
Stranded
yes
1)
1)
Note: max. 25 m can be crossed unstranded.
(CH: Applies also to cable type G51)
Wire diameter, core
0.4…0.6 mm
Screening
recommended
Characteristic impedance
< 130
(1 MHz)
1)
Applies in Australia only