Operation and Maintenance
209
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
6. 4. 3. 5
Boot Command Mode
The Boot Command Mode is used to carry out a first start or set a fixed IP address.
The Boot Command Mode is indicated by the SYS-LED flashing orange-red.
The Boot Command Mode is entered by pressing and holding down the control key
(LC) during the start-up state (see pattern
[5]
,
Tab. 89
). Pattern
[18]
is displayed once
the Boot Command Mode has been entered.
Tab. 93
Patterns after entering the Boot Command Mode
The Boot Command Mode is exited automatically if no input is made within 20 sec-
onds; the system returns to Startup Mode and restarts.
6. 4. 3. 6
Wiring Adapter Malfunction Mode
The system switches to this mode if an unsuitable wiring adapter is fitted into one
of the wiring adapter slots. Missing wiring adapters are also indicated.
The Wiring Adapter Malfunction Mode is indicated by one or more red flashing
LEDs F1...F4. The LED number corresponds to the number of the Wiring Adapter
slot concerned. The SYS-LED flashes green as in the Normal Mode.
Tab. 94
Sample pattern for Wiring Adapter Malfunction Mode
Pat-
tern
No.
F0
F1
F2
F3
F4
SYS
Meaning
[18]
Boot Command Mode active
Pattern
No.
F0
F1
F2
F3
F4
SYS
Meaning
[20]
Incorrect or missing wiring adapter in slot
WA2
R
–
–
–
–
O R
–
–
–
R
–
–
–
G