![4RF Aprisa XE User Manual Download Page 36](http://html.mh-extra.com/html/4rf/aprisa-xe/aprisa-xe_user-manual_445266036.webp)
Mounting and installing the terminal | 35
AC power supply
There is one AC power supply for the terminal. This AC power supply is auto-sensing to operate with a
nominal input voltage of 115 Vrms or 230 Vrms.
The power input is terminated on the front panel of the terminal using a standard IEC plug. This power
supply has a power on/off switch.
A power cable is included in the accessory kit and is pre-fitted with an IEC socket connector and the
country-specific plug that was specified when the order was placed.
Nominal
voltage
Input voltage
range
Power consumption
Max VA
Frequency
115 VAC
103 - 127 Vrms
63 - 180 W
400 VA
47 - 63 Hz
230 VAC
207 - 254 Vrms
63 - 180 W
400 VA
47 - 63 Hz
Terminal
Power input
Cable colour
E Earth Green/yellow
N Neutral Blue
L
Line / Phase
Brown
Important:
Please check with your local power authority about correct colour usage and pinouts. AC
power cords used must be in accordance with national requirements.
Norway and Sweden:
PLUGGABLE CLASS I EQUIPMENT intended for connection to a telephone
network or similar communications system requires a label stating that the equipment must be
connected to an earthed mains socket outlet.
Summary of Contents for Aprisa XE
Page 1: ...Aprisa XE User Manual Version 7 3 1 September 2006 ...
Page 5: ......
Page 11: ......
Page 15: ......
Page 39: ......
Page 51: ......
Page 61: ......
Page 163: ......
Page 217: ...Interface connections 216 ...
Page 235: ......
Page 255: ......
Page 257: ......
Page 259: ......
Page 265: ......
Page 266: ...Commissioning Forms 265 22 Commissioning Forms ...
Page 267: ...Commissioning Forms 266 ...
Page 272: ...Index 271 W web browser cache clearing 180 WEEE 255 ...