![4RF Aprisa XE User Manual Download Page 33](http://html.mh-extra.com/html/4rf/aprisa-xe/aprisa-xe_user-manual_445266033.webp)
Mounting and installing the terminal | 32
Interface cabling
All interface cabling connections are made with RJ-45 male connectors which plug into the front of the
interface cards (see “Interface connections” on page 211).
The cabling to the QJET, DFXO and DFXS interface cards must have a minimum conductor size of
0.4 mm2 (26 AWG).
Power supplies
US and Canada:
Installations should be in accordance with US National Electrical Code ANSI /
NFPA 70, and Canadian Electrical Code, Part 1 C22.1.
Warning:
Do not apply power to the terminal until you have completed installing
the interface cards and connecting the antenna.
Warning:
Before disconnecting the safety earth during maintenance, remove AC
or DC power supply connections, antenna cable and all interface cables from the
terminal.
DC power supply
There are three DC power supplies for the terminal 12 VDC, 24 VDC and 48 VDC.
As the terminal DC input is isolated above ground, the DC power input can be either positive grounded
or negative grounded.
Nominal
voltage
Input voltage
range
Power
consumption
Maximum
input current
Recommended DC
breaker rating
±12 VDC
10.5 to 18 VDC
63 - 180 W
18 A
25 A
±24 VDC
20.5 to 30 VDC
63 - 180 W
8 A
10 A
±48 VDC
40 to 60 VDC
63 - 180 W
4 A
5 A
Caution:
An all-pole switch or DC circuit breaker of the rating shown in the table above must be fitted
between the terminal DC input and the DC power source.
Each terminal or MHSB terminal should have its own separate fuse or DC circuit breaker.
Summary of Contents for Aprisa XE
Page 1: ...Aprisa XE User Manual Version 7 3 1 September 2006 ...
Page 5: ......
Page 11: ......
Page 15: ......
Page 39: ......
Page 51: ......
Page 61: ......
Page 163: ......
Page 217: ...Interface connections 216 ...
Page 235: ......
Page 255: ......
Page 257: ......
Page 259: ......
Page 265: ......
Page 266: ...Commissioning Forms 265 22 Commissioning Forms ...
Page 267: ...Commissioning Forms 266 ...
Page 272: ...Index 271 W web browser cache clearing 180 WEEE 255 ...