Cross Connections | 145
QV24 cross connections
1.
Expand the QV24 displays, as required, by clicking the relevant icons.
2.
Select the Port Baud Rate as required (default is 9600).
3.
Drag and drop to the required partner interface to create the V.24 Data connection.
If the partner interface is a QJET:
If the V.24 Baud Rate selected is 38400 is less, drag from the QV24 mapping connection box
to the QJET timeslot. The correct QJET capacity for the baud rate selected will automatically
be assigned.
If the V.24 Baud Rate selected is greater than 38400, select the QJET capacity required, as
per the following table, and drag from the QJET to the QV24 mapping connection box.
Baud Rate
Bits Required
Bit Rate
300 - 7200
2
16 kbit/s
9600 - 14400
3
24 kbit/s
19200 - 23040
4
32 kbit/s
28800 5 40
kbit/s
38400 6 48
kbit/s
57600 9 72
kbit/s
115200 16 128
kbit/s