![4RF Aprisa XE User Manual Download Page 253](http://html.mh-extra.com/html/4rf/aprisa-xe/aprisa-xe_user-manual_445266253.webp)
Specifications | 252
Power specifications
AC Power supply
Nominal
voltage
Input voltage
range
Power consumption
Max VA
Frequency
115 VAC
103 - 127 Vrms
63 - 180 W
400 VA
47 - 63 Hz
230 VAC
207 - 254 Vrms
63 - 180 W
400 VA
47 - 63 Hz
DC Power supply
Nominal
voltage
Input voltage
range
Power consumption
Maximum input current
±12 VDC
10.5 to 18 VDC
63 - 180 W
18 A
±24 VDC
20.5 to 30 VDC
63 - 180 W
8 A
±48 VDC
40 to 60 VDC
63 - 180 W
4 A
Power consumption
Power Consumption
(min – max)
63 - 180 W Input power (dependent on interface cards fitted and
modulation type / output power level)
Terminal only:
QPSK + 19 dBm
65 W
QPSK + 29 dBm
68 W
QPSK + 32 dBm
72 W
QPSK + 35 dBm
75 W
64 QAM + 15 dBm
63 W
64 QAM + 29 dBm
71 W
Interface cards:
QJET four port E1 card
1.9 W (all states)
Q4EM four port 4W E&M card
0.75 W (all states)
QV24 four port V.24 card
0.75 - 1 W (all states)
DFXO two port 2W FXO card
0.75 W (all states)
DFXS two port 2W FXS card
One DFXS card installed with both ports idle (on hook): 3.8 W
Plus:
1.3 W / line off-hook (200 ohm copper loop plus 450 ohm
telephone)
2.6 W / line ringing (60 Vrms 25Hz source via 50 ohm copper loop
into a 1 REN load)
4.1 W / line ringing (45 Vrms 25Hz source via 50 ohm copper loop
into a 3 REN load)
HSS single port high speed data
1 W (all states)
MHSB:
Tributary and RF switch
16 W not switched
28 W switched
Summary of Contents for Aprisa XE
Page 1: ...Aprisa XE User Manual Version 7 3 1 September 2006 ...
Page 5: ......
Page 11: ......
Page 15: ......
Page 39: ......
Page 51: ......
Page 61: ......
Page 163: ......
Page 217: ...Interface connections 216 ...
Page 235: ......
Page 255: ......
Page 257: ......
Page 259: ......
Page 265: ......
Page 266: ...Commissioning Forms 265 22 Commissioning Forms ...
Page 267: ...Commissioning Forms 266 ...
Page 272: ...Index 271 W web browser cache clearing 180 WEEE 255 ...