3M™ Dual Airline Replacement Parts

Product 

Number

AAD Number*

Description of Front-Mounted Dual Airline Components

SA-1000

Front-Mounted Adapter Kit (includes SA-1500 breathing tube and SA-1007 

regulator assembly)

SA-1000LP

Front-Mounted Adapter Kit, Low Pressure (includes SA-1500 breathing tube and 

SA-1027 low pressure connector assembly)

SA-1500

07147

Front-Mounted Breathing Tube

SA-1600

Combination Front-Mounted Breathing Tube

SA-1100

Combination Front-Mounted Adapter Kit (includes SA-1600 breathing tube and 

SA-1007 regulator assembly)

SA-1100LP

Combination Front-Mounted Adapter Kit, Low Pressure (includes SA-1600 breathing 

tube and SA-1027 low pressure connector assembly)

Product 

Number

AAD Number*

Description of Back-Mounted Dual Airline Components

SA-2000

Back-Mounted Adapter Kit (includes SA-2500 back-mounted breathing tube and 

SA-1007 regulator assembly)

SA-2000LP

Back-Mounted Adapter Kit, Low Pressure (includes SA-2500 back-mounted 

breathing tube and SA-1027 low pressure connector assembly)

SA-2500

07148

Back-Mounted Breathing Tube

SA-2600

37001

Combination Back-Mounted Breathing Tube

SA-2100

Combination Back-Mounted Adapter Kit (includes SA-2600 back-mounted breathing 

tube and SA-1007 regulator assembly)

SA-2100LP

Combination Back-Mounted Adapter Kit, Low Pressure (includes SA-2600 back-

mounted breathing tube and SA-1027 low pressure connector assembly)

Product 

Number

AAD Number*

Description of Air Control Valves, Connectors and Fittings

SA-1007

07153

Air Regulating Valve Assembly, Industrial Interchange Fitting (includes SA-1009 

valve and GVP-127 belt)

SA-1009

07149

Air Regulating Valve, Industrial Interchange

SA-1027

07154

Connector Assembly, Low Pressure (includes SA-1029 connector and GVP-127 

web belt)

SA-1029

07150

Connector, Low Pressure

GVP-127

07152

Waist Belt, Web (up to ~ 46”)

W-2963

07045

Waist Belt, Cotton (up to ~ 43”)

W-3217

Waist Belt, Vinyl (up to ~ 54”)

520-02-23

Waist Belt, Decontaminable (up to ~ 50”)

6880 

37002

Bayonet Caps (10 caps/case)

W-1279-2

Plug, 1/4 in Body Size, 1/4 in MPT, Industrial Interchange (High Pressure)

W-3186-2

Plug, 1/4 in Body Size, 1/4 in MPT, Schrader (High Pressure)

W-3251-2

Plug, 1/2 in Body Size, 1/4 in MPT, Schrader (Low Pressure)

W-3252-2

Plug, 3/8 in Body Size, 1/4 in MPT, Industrial Interchange (Low Pressure)

*  3M Automotive Aftermarket Division (AAD). AAD part numbers are catalog numbers only. NIOSH approved by the 

corresponding 3M PSD Division product number.

3M™ Dual Airline System Kits for Automotive Industry Users

AAD Product Number*

Description of Back-Mounted Low Pressure Combination Dual Airline Kits

37030

Half Facepiece Kit [includes 07025 medium half facepiece, 37001 combination breathing 

tube, 07154 connector assembly, 07034 low pressure hose, 50 ft, 07046 organic vapor 

cartridges (1 pair), 07054 fi lter retainers (1 pair), and 07194 fi lters, P95 (2 pair)]

37031

Half Facepiece Kit [includes the same components as the 37030 kit, except with 07026 

large half facepiece]

37032

Full Facepiece Kit [includes the same components as the 37030 kit, except with 07139 

medium full facepiece and 1 pack (25 ea.) 07142 faceshield covers]

37033

Full Facepiece Kit [includes the same components as the 37030 kit, except with 07140 

large full facepiece and 1 pack (25 ea.) 07142 faceshield covers]

AAD Product Number*

Description of Back-Mounted High Pressure Combination Dual Airline Kits

37034

Half Facepiece Kit [includes 07025 medium half facepiece, 37001 combination breathing 

tube, 07153 air regulator assembly, 07011 high pressure hose, 50 ft, 07046 organic vapor 

cartridges (1 pair), 07054 fi lter retainers (1 pair), and 07194 fi lters, P95 (2 pair)]

37035

Half Facepiece Kit [includes the same components as the 37034 kit, except with 07026 

large half facepiece]

37036

Full Facepiece Kit [includes the same components as the 37034 kit, except with 07139 

medium full facepiece. and 1 pack (25 ea.) 07142 faceshield covers]

37037

Full Facepiece Kit [includes the same components as the 37034 kit, except with 07140 

large full facepiece and 1 pack (25 ea.) 07142 faceshield covers]

*  3M Automotive Aftermarket Division (AAD). The 07XXX and 37XXX AAD numbers are catalog numbers only. 

ASSEMBLY 

W

 WARNING

Failure to follow these instructions may reduce respirator performance, overexpose you to contaminants, and 

may result 

in sickness or death.

•  If the facepiece is to be used as an air purifying facepiece (without using the 3M™ Combination Dual Airline Breathing 

Tubes SA-1600 or SA-2600), the inhalation valves MUST be replaced in the facepiece before use. 

•  Failure to use thread tape when replacing the breathing tube may result in damage to the female threads in the cap of 

the air control valve and prevent a tight fi t and result in leakage.

The instructions for converting 3M™ Half Facepiece Respirators and 3M™ Full Facepiece Respirators for dual airline 

supplied air applications are presented in this section. To set up a correct and complete assembly, follow the directions 

below. Refer to the NIOSH approval label for approved respirator confi gurations.

3M™ Half Facepiece Respirators (6000 Series Shown)

SA-1500

Fig. 2

SA-2500

 

Fig. 3

Summary of Contents for SA-1500

Page 1: ...ess mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer IC Socket Relay Connector Our parts cover such applications as commercial industrial and automotives areas We are looking forward to setting up business relationship with you and hope to provide you...

Page 2: ...stro de línea dual de aire Instrucciones Respiradores de Suprimento de Ar e Traquéia Dupla Instruções de Uso IMPORTANT Keep these User Instructions for reference REMARQUE IMPORTANTE Conserver ces directives d utilisation à titre de référence IMPORTANTE Conserve estas Instrucciones para referencia futura IMPORTANTE Guarde estas Instruções de Uso para consulta ...

Page 3: ...eathing Tubes 11 OPERATING INSTRUCTIONS 12 General Instructions 12 Performance Check 12 Donning 13 Donning and Adjusting 3M Half Facepiece Respirators 13 Donning and Adjusting 3M Full Facepiece Respirators 13 User Seal Checks Must be Performed Each Time Respirator is Worn 14 INSPECTION CLEANING AND STORAGE 14 Cleaning Disinfecting 14 Inspecting the Facepiece 15 Inspecting the Air Control Valves 15...

Page 4: ...icult You feel dizzy or your vision is impaired You taste or smell contaminants Your face eyes nose or mouth become s irritated You suspect that the concentration of contaminants may have reached levels at which this respirator may no longer provide adequate protection W WARNING DO NOT remove the facepiece nose cup The 3M Dual Airline Breathing Tube is only approved for use with the nose cup insta...

Page 5: ... airline breathing tubes SA 1600 or SA 2600 with filters and or cartridges Store the inhalation valves so they remain flat and free of contamination Air Supply Requirements for 3M Dual Airline Systems with 3M Ultimate FX Full Facepiece Respirator FF 400 Series 3M Dual Airline and 3M Ultimate FX Full Facepiece Respirator FF 400 Series system approvals allow you to combine up to three W 9435 or W 94...

Page 6: ... Relief Valve Check Valve Pressure Regulator Hose Small Particle Airline Filter Fig 1 Oil mist from the compressor lubricating oil must not be present when the air reaches the air control device Excessive amounts of water vapor and any particulate matter should also be removed as they may result in unpredictable behavior of the air control device The schematic diagram Fig 1 of the air purifier and...

Page 7: ...Airline System Kits for Automotive Industry Users AAD Product Number Description of Back Mounted Low Pressure Combination Dual Airline Kits 37030 Half Facepiece Kit includes 07025 medium half facepiece 37001 combination breathing tube 07154 connector assembly 07034 low pressure hose 50 ft 07046 organic vapor cartridges 1 pair 07054 filter retainers 1 pair and 07194 filters P95 2 pair 37031 Half Fa...

Page 8: ...al airline breathing tube to the 3M Full Facepiece 7800S Fig 10 3 Thread the assembled 3M Bayonet Adapter 701 into the cartridge connector port do not tighten the orange gasket will be facing outward Align the small solid bayonet lug to the bottom of the facepiece lens and tighten the nut Place another 3M Bayonet Adapter 701 in the opposite cartridge connector port following the same procedure Fig...

Page 9: ...tely if any of the following conditions occur Any part of the system becomes damaged Airflow into the respirator decreases or stops Breathing becomes difficult You feel dizzy or your vision is impaired You taste or smell contaminants Your face eyes nose or mouth become s irritated You suspect that the concentration of contaminants may have reached levels at which this respirator may no longer prov...

Page 10: ...f using the 3M Combination Breathing Tubes SA 1600 or SA 2600 in conjunction with 3M Cartridge 6000 Series 3M Particulate Filter 2000 Series follow the appropriate positive and negative pressure user seal check instructions Positive Pressure User Seal Check Place the palm of your hand over opening in exhalation valve cover and exhale gently If the facepiece bulges slightly and no air leaks are det...

Page 11: ...aminants or irritation occurs or breathing becomes difficult or dizziness or other distress occurs Equipment malfunction Incorrect assembly Misuse Pressure not within manufacturer s guidelines Leave the work area immediately and notify your supervisor Do not use the dual airline system until the performance check in the Assembly Section of this User Instruction is completed and the equipment is ch...

Page 12: ...20 Facteurs de protection caractéristiques 21 Avertissements et restrictions du NIOSH 21 S Directives d utilisation spéciales ou d importance capitale 21 Exigences d alimentation d air pour les systèmes à deux arrivées d air 3MMC avec respirateur à masque complet ultra FX 3MMC de série FF 400 21 Exigences relatives à l alimentation en air pour les systèmes à deux arrivées d air 3MMC 22 SPÉCIFICATI...

Page 13: ...ristique FPC recommandé pour le système de protection respiratoire utilisé ou au FPC établi par des normes gouvernementales spécifiques selon la valeur la moins élevée W MISE EN GARDE Les contaminants dangereux pour la santé englobent les particules trop petites pour être senties ou être visibles à l œil nu Quitter immédiatement la zone contaminée si l une ou l autre des conditions ci dessous surv...

Page 14: ...et l entretien de ces respirateurs P Le NIOSH n évalue pas les respirateurs comme masques chirurgicaux S Des directives d utilisation spéciales ou d importance capitale et ou des restrictions d utilisation spécifiques s appliquent Consulter les directives d utilisation avant la mise en place de ce produit S Directives d utilisation spéciales ou d importance capitale Retirer les soupapes d inhalati...

Page 15: ...pet de retenue Régulateur de pression Tuyau Filtre du tuyau d air comprimé contre les petites particules Fig 1 Il ne doit pas y avoir de brouillard d huile provenant de l huile de lubrification du compresseur lorsque l air atteint les dispositifs de régulation d air L excès de vapeur d eau et de particules doit également être enlevé car il peut provoquer le fonctionnement imprévisible du dispositi...

Page 16: ...ogués par le NIOSH avec les numéros de la Division des produits de protection individuelle de 3M Trousses de système à deux arrivées d air 3MMC pour l industrie automobile Numéro de produit de la Division du marché après vente pour l automobile Description des trousses de composants montés à l arrière pour systèmes combinés basse pression à deux arrivées d air 37030 Trousse de demi masque comprend...

Page 17: ...n pointe en direction opposée du logo 3M situé à l avant du demi masque Fig 2 et 3 2 Tourner de un quart de tour les deux extrémités du tuyau de respiration dans le sens des aiguilles d une montre jusqu à ce qu elles s enclenchent fermement dans les raccords de verrouillage et ne puissent plus tourner Ne pas exercer trop de force en tournant car cela risque d endommager le dispositif de verrouilla...

Page 18: ... la protection respiratoire voulue puis les relier aux baïonnettes extérieures du tuyau de respiration combiné à deux arrivées d air SA 1600 ou SA 2600 3MMC Fig 18 4 Mettre le masque conformément aux procédures énoncées dans la section Mise en place des présentes directives d utilisation 5 Une fois le respirateur adéquatement ajusté effectuer un essai d ajustement par pression positive ou négative...

Page 19: ...établi ou selon l indicateur de fin de durée utile IFDU Remplacer les cartouches immédiatement si l on décèle un goût ou une odeur de contaminant ou si une irritation se manifeste Remplacer les filtres immédiatement s ils sont endommagés encrassés ou si la respiration devient difficile Ne pas utiliser les filtres de série N en présence d aérosols à base d huile Utiliser les filtres de série R pend...

Page 20: ... courroies afin d éliminer les fuites Si l on ne peut obtenir un ajustement parfaitement étanche NE PAS pénétrer dans la zone contaminée Consulter son superviseur REMARQUE Avant de porter un respirateur dans des zones contaminées effectuer un essai d ajustement qualitatif ou quantitatif conformément aux exigences applicables de la norme respiratoire 29 CFR 1910 134 de l OSHA Au Canada se conformer...

Page 21: ...e l eau et un détergent doux AVIS IMPORTANT GARANTIE Si un produit de la Division des produits de protection individuelle de 3M présente un défaut de matériau ou de fabrication ou s il n est pas conforme à toute garantie explicite d adaptation à un usage particulier la seule obligation de 3M qui constitue votre seul recours est au gré de 3M de réparer ou de remplacer toute pièce ou tout produit dé...

Page 22: ...antes sean inmediatamente peligrosas para la vida o salud IDLH Las concentraciones de contaminantes excedan la MUC determinada con el APF para el sistema respirador específico o el APF estipulado por las normas gubernamentales correspondientes lo que sea menor W ADVERTENCIA Los contaminantes peligrosos para su salud incluyen aquellos que no puede ver u oler Abandone el área contaminada de inmediat...

Page 23: ...Aplican las Instrucciones especiales o importantes y o limitaciones de uso específicas Antes del uso del equipo consulte las Instrucciones S Instrucciones especiales o importantes Antes de la instalación de la combinación de Tubos de respiración de línea de aire dual SA 1600 o SA 2600 con filtros o cartuchos retire las válvulas de inhalación del Respirador de pieza facial de cara completa o media ...

Page 24: ...cualquier partícula ya que afectan el desempeño de las válvulas para el control de aire El diagrama Fig 1 del purificador de aire y el equipo regulador de presión muestra lo que se debe instalar en la línea de aire principal antes de la conexión para las mangueras de aire respirable Si se desea usar un filtro de aire pre ensamblado y un dispositivo regulador 3M ofrecer varios filtros paneles regul...

Page 25: ...cial de media cara grande 07026 37032 Kit de pieza facial de cara completa incluye los mismos componentes que el kit 37030 excepto con pieza facial de cara completa mediana 07139 y 1 paquete 25 c u Cubiertas para protector facial 07142 37033 Kit de pieza facial de cara completa incluye los mismos componentes que el kit 37030 excepto con pieza facial de cara completa grande 07140 y 1 paquete 25 c u...

Page 26: ... de 3M en el tubo de respiración y el frente de la pieza facial queden mirando hacia usted Para los Tubos de respiración 3M SA 2500 o SA 2600 asegúrese que el logotipo 3M en el tubo de respiración quede mirando en la dirección opuesta al logotipo 3M en el frente de la pieza facial Fig 12 Gire cada derivación del tubo de respiración un cuarto de vuelta en sentido de las manecillas del reloj hasta q...

Reviews: