GENERAL SAFETY INFORMATION

Intended Use

The 3M™ Half Facepiece Respirator 6000

1

 and 3M™ Half Facepiece Respirator 7500

2

 Series, 3M™ Full Facepiece 

Respirator 7800S, 6000

3

/6000DIN, and 3M™ Ultimate FX Full Facepiece Respirator FF-400 Series can be converted to 

continuous fl ow, supplied air respirators when used with the 3M™ Dual Airline Breathing Tubes SA-1500 and SA-2500. 

These facepieces can also be converted to combination air purifying/supplied air respirators when the 3M™ Combination 

Dual Airline Breathing Tubes SA-1600 and SA-2600

4

 are used in conjunction with certain NIOSH approved 3M™ Half 

Facepiece Respirator 6000 Series Cartridges and Prefi lters and 3M™ Particulate Filter 2000 Series Filters. 

These conversions require one of the dual airline positive pressure adapter kits (see the 

System Components and 

Replacement Parts

 section of these 

User Instructions

).

1

  07024, 07025 and 07026 are automotive product numbers for the 6100, 6200 and 6300 half facepieces.

2

  37081, 38082, 37083 are automotive product numbers for the 7501, 7502 and 7503 half facepieces.

3

  07138, 07139, 07140 are automotive product numbers for the 6700, 6800 and 6900 full facepieces.

4

  37001 is an automotive product number for SA-2600.

Listing of Warnings and Cautions within these 

User Instructions

W

 WARNING

Failure to follow these instructions may reduce respirator performance, overexpose you to contaminants, and 

may result 

in sickness or death.
• 

This product helps protect against certain airborne contaminants. For proper use, see supervisor, 

User Instructions

 or 

call 3M in U.S.A., 1-800-243-4630. In Canada, call Technical Service at 1-800-267-4414.

• 

Each person using these respirators must read and understand the information in these 

User Instructions

 before 

use. Respirators must be used in accordance with these 

User Instructions

, and must not be used by untrained or 

unqualifi ed persons.

• 

Not all 3M™ Cartridge 6000 Series/3M™ Particulate Filter 2000 Series combinations are approved for use with the 

3M™ Combination Dual Airline Breathing Tubes SA-1600/SA-2600. Review the NIOSH approval label prior to using 

the equipment. 

• 

To meet the NIOSH requirement 42 CFR 84, Subpart 84.150 for minimum and maximum airfl ow (4 to 15 cfm, 113 to 

425 lpm), the air control valves approved for use with the 3M™ Dual Airline Respirators must be operated within the 

supply pressure ranges and hose lengths stated in the 

Air Supply Requirements

 table in this 

User Instruction

• 

You must comply with Occupational Safety and Health Administration (OSHA) standard 29 CFR 1910.134, which states 

that, “Airline couplings shall be incompatible with outlets for other gas systems to prevent inadvertent servicing of 

airline respirators with nonrespirable gases or oxygen”. In Canada, refer to CSA standard Z180.1 or the requirements 

of the authority having jurisdiction in your region. 

• 

Your employer must provide compressed breathing air that meets at least the requirements of the specifi cation for 

Grade D breathing air, as described in the Compressed Gas Association Commodity Specifi cation G-7.1 in the United 

States. In Canada, refer to CSA standard Z180.1 table for the quality of compressed breathing air. 

• 

The line pressure must be kept within safe limits, 125 psig (8.75 kg/cm

2

) maximum. Dirt, oil and water, unless trapped 

or fi ltered out, may continue downstream in concentrated form and adversely affect the performance of the respirator.

• 

If the facepiece is to be used as an air purifying facepiece (without using the 3M™ Combination Dual Airline Breathing 

Tubes SA-1600 or SA-2600), the inhalation valves MUST be replaced in the facepiece before use. 

• 

Failure to use thread tape when replacing the breathing tube may result in damage to the female threads in the cap of 

the air control valve and prevent a tight fi t and result in leakage. 

• 

Do not wear this respirator to enter areas for which it is not NIOSH certifi ed or designed, including areas where:
–  Atmospheres are oxygen defi cient. 
–  Contaminant concentrations are unknown.
–  Contaminant concentrations are Immediately Dangerous to Life or Health (IDLH).
–  Contaminant concentrations exceed the Maximum Use Concentration (MUC) determined using the Assigned 

Protection Factor (APF) for the specifi c respirator system or the APF mandated by specifi c government standards, 

whichever is lower. 

• 

Contaminants that are dangerous to your health include those that you may not be able to see or smell. Leave the 

contaminated area immediately if any of the following conditions occur. 
–  Any part of the system becomes damaged.
–  Airfl ow into the respirator decreases or stops.
–  Breathing becomes diffi cult.
–  You feel dizzy or your vision is impaired.
–  You taste or smell contaminants.
–  Your face, eyes, nose or mouth become(s) irritated.
–  You suspect that the concentration of contaminants may have reached levels at which this respirator may no longer 

provide adequate protection.

W

 WARNING

• 

DO NOT remove the facepiece nose cup. The 3M™ Dual Airline Breathing Tube is only approved for use with the 

nose cup installed. 

• 

Do not enter a contaminated area until the respirator system has been properly donned. Do not remove the respirator 

before leaving the contaminated area. 

• 

If this respirator system fails any of the requirements of the user inspection and performance check, do not use the 

respirator until all necessary repairs have been made and the respirator passes the performance check. 

• 

Before using any respirator with a negative or positive pressure tight-fi tting facepiece, the employee must be fi t tested 

with the same make, model, style and size of respirator that will be used. Fit testing is required by OSHA’s Respiratory 

Protection standard 29 CFR 1910.134. In Canada, follow CSA standard Z94.4 or the requirements of the authority 

having jurisdiction in your region.

• 

As part of a good industrial hygiene program and as stated in the OSHA respiratory protection standard 29 CFR 

1910.134 and in the CSA standard Z94.4 “Selection, Use and Care of Respirators”, a tight fi tting facepiece must not 

be worn with beards or other facial hair or other conditions that prevent a good seal between the face and the sealing 

surface of the respirator.

• 

Never modify or alter this respirator. Repair or replace parts only with approved 3M components.

 CAUTION

Do not immerse the air regulator or low pressure connector in water; doing so may saturate the foam spring valve with 

water. Failure to dry the foam may result in the growth of mold or mildew.

Important

Before use, wearer must read and understand these 

User Instructions

. Keep these 

User Instructions

 for reference.

Respirator Selection and Training

Use of these respirators must be in accordance with applicable health and safety standards, respirator selection tables 

contained in such publications as American National Standards Institute (ANSI) Z88.2-1992, Canadian Standards Association 

(CSA) Standard Z94.4 or pursuant to the recommendations of an industrial hygienist. The employer must have a written 

respirator program in place that complies with the Occupational Safety and Health Administration (OSHA) respiratory 

protection standard found in 29 CFR 1910.134 prior to using any respirator. In Canada, follow CSA standard Z94.4 or the 

requirements of the authority having jurisdiction in your region.

Before use, the employer must assure that each respirator user has been trained by a qualifi ed person in the proper use 

and maintenance of the respirator according to the instructions contained in these 

User Instructions

 and other applicable 

User Instructions

.

W

 WARNING

Failure to follow these instructions may reduce respirator performance, overexpose you to contaminants, and 

may result 

in sickness or death.

•  Each person using these respirators must read and understand the information in these 

User Instructions

 before 

use. Respirators must be used in accordance with these 

User Instructions

, and must not be used by untrained or 

unqualifi ed persons.

•  Not all 3M™ Cartridge 6000 Series/3M™ Particulate Filter 2000 Series combinations are approved for use with the 

3M™ Combination Dual Airline Breathing Tubes SA-1600/SA-2600. Review the NIOSH approval label prior to using 

the equipment. 

National Institute for Occupational Safety and Health (NIOSH) Approvals 

The 3M™ Dual Airline Systems utilizing the SA-1500, SA-2500, SA-1600 or SA-2600 breathing tubes are National Institute 

for Occupational Safety and Health (NIOSH) approved for use as Type C, continuous fl ow supplied air respirators. When using 

SA-1600 or SA-2600 combination breathing tubes without cartridges or fi lters, 3M™ Bayonet Caps 6880 are required. 

Additionally, the dual airline systems utilizing the 3M™ Combination Dual Airline Breathing Tubes SA-1600 or SA-2600 are 

NIOSH approved for use as combination, air purifying, and air supplied respirators. The approval numbers for these respirator 

systems can be obtained by referencing the NIOSH approval labels. 

When disconnected from the air source, the 3M™ Combination Dual Airline Breathing Tubes SA-1600 and SA-2600 

used in conjunction with approved facepieces, cartridges and fi lters convert to an air purifying respirator. Depending on 

the contaminant and concentration levels, this may facilitate entry and egress from the work area, while maintaining 

respiratory protection.

NOTE:

 The assigned protection factor for the respirator varies depending upon the mode of operation. Reference the 

assigned protection factor table.

Summary of Contents for SA-1500

Page 1: ...ess mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer IC Socket Relay Connector Our parts cover such applications as commercial industrial and automotives areas We are looking forward to setting up business relationship with you and hope to provide you...

Page 2: ...stro de línea dual de aire Instrucciones Respiradores de Suprimento de Ar e Traquéia Dupla Instruções de Uso IMPORTANT Keep these User Instructions for reference REMARQUE IMPORTANTE Conserver ces directives d utilisation à titre de référence IMPORTANTE Conserve estas Instrucciones para referencia futura IMPORTANTE Guarde estas Instruções de Uso para consulta ...

Page 3: ...eathing Tubes 11 OPERATING INSTRUCTIONS 12 General Instructions 12 Performance Check 12 Donning 13 Donning and Adjusting 3M Half Facepiece Respirators 13 Donning and Adjusting 3M Full Facepiece Respirators 13 User Seal Checks Must be Performed Each Time Respirator is Worn 14 INSPECTION CLEANING AND STORAGE 14 Cleaning Disinfecting 14 Inspecting the Facepiece 15 Inspecting the Air Control Valves 15...

Page 4: ...icult You feel dizzy or your vision is impaired You taste or smell contaminants Your face eyes nose or mouth become s irritated You suspect that the concentration of contaminants may have reached levels at which this respirator may no longer provide adequate protection W WARNING DO NOT remove the facepiece nose cup The 3M Dual Airline Breathing Tube is only approved for use with the nose cup insta...

Page 5: ... airline breathing tubes SA 1600 or SA 2600 with filters and or cartridges Store the inhalation valves so they remain flat and free of contamination Air Supply Requirements for 3M Dual Airline Systems with 3M Ultimate FX Full Facepiece Respirator FF 400 Series 3M Dual Airline and 3M Ultimate FX Full Facepiece Respirator FF 400 Series system approvals allow you to combine up to three W 9435 or W 94...

Page 6: ... Relief Valve Check Valve Pressure Regulator Hose Small Particle Airline Filter Fig 1 Oil mist from the compressor lubricating oil must not be present when the air reaches the air control device Excessive amounts of water vapor and any particulate matter should also be removed as they may result in unpredictable behavior of the air control device The schematic diagram Fig 1 of the air purifier and...

Page 7: ...Airline System Kits for Automotive Industry Users AAD Product Number Description of Back Mounted Low Pressure Combination Dual Airline Kits 37030 Half Facepiece Kit includes 07025 medium half facepiece 37001 combination breathing tube 07154 connector assembly 07034 low pressure hose 50 ft 07046 organic vapor cartridges 1 pair 07054 filter retainers 1 pair and 07194 filters P95 2 pair 37031 Half Fa...

Page 8: ...al airline breathing tube to the 3M Full Facepiece 7800S Fig 10 3 Thread the assembled 3M Bayonet Adapter 701 into the cartridge connector port do not tighten the orange gasket will be facing outward Align the small solid bayonet lug to the bottom of the facepiece lens and tighten the nut Place another 3M Bayonet Adapter 701 in the opposite cartridge connector port following the same procedure Fig...

Page 9: ...tely if any of the following conditions occur Any part of the system becomes damaged Airflow into the respirator decreases or stops Breathing becomes difficult You feel dizzy or your vision is impaired You taste or smell contaminants Your face eyes nose or mouth become s irritated You suspect that the concentration of contaminants may have reached levels at which this respirator may no longer prov...

Page 10: ...f using the 3M Combination Breathing Tubes SA 1600 or SA 2600 in conjunction with 3M Cartridge 6000 Series 3M Particulate Filter 2000 Series follow the appropriate positive and negative pressure user seal check instructions Positive Pressure User Seal Check Place the palm of your hand over opening in exhalation valve cover and exhale gently If the facepiece bulges slightly and no air leaks are det...

Page 11: ...aminants or irritation occurs or breathing becomes difficult or dizziness or other distress occurs Equipment malfunction Incorrect assembly Misuse Pressure not within manufacturer s guidelines Leave the work area immediately and notify your supervisor Do not use the dual airline system until the performance check in the Assembly Section of this User Instruction is completed and the equipment is ch...

Page 12: ...20 Facteurs de protection caractéristiques 21 Avertissements et restrictions du NIOSH 21 S Directives d utilisation spéciales ou d importance capitale 21 Exigences d alimentation d air pour les systèmes à deux arrivées d air 3MMC avec respirateur à masque complet ultra FX 3MMC de série FF 400 21 Exigences relatives à l alimentation en air pour les systèmes à deux arrivées d air 3MMC 22 SPÉCIFICATI...

Page 13: ...ristique FPC recommandé pour le système de protection respiratoire utilisé ou au FPC établi par des normes gouvernementales spécifiques selon la valeur la moins élevée W MISE EN GARDE Les contaminants dangereux pour la santé englobent les particules trop petites pour être senties ou être visibles à l œil nu Quitter immédiatement la zone contaminée si l une ou l autre des conditions ci dessous surv...

Page 14: ...et l entretien de ces respirateurs P Le NIOSH n évalue pas les respirateurs comme masques chirurgicaux S Des directives d utilisation spéciales ou d importance capitale et ou des restrictions d utilisation spécifiques s appliquent Consulter les directives d utilisation avant la mise en place de ce produit S Directives d utilisation spéciales ou d importance capitale Retirer les soupapes d inhalati...

Page 15: ...pet de retenue Régulateur de pression Tuyau Filtre du tuyau d air comprimé contre les petites particules Fig 1 Il ne doit pas y avoir de brouillard d huile provenant de l huile de lubrification du compresseur lorsque l air atteint les dispositifs de régulation d air L excès de vapeur d eau et de particules doit également être enlevé car il peut provoquer le fonctionnement imprévisible du dispositi...

Page 16: ...ogués par le NIOSH avec les numéros de la Division des produits de protection individuelle de 3M Trousses de système à deux arrivées d air 3MMC pour l industrie automobile Numéro de produit de la Division du marché après vente pour l automobile Description des trousses de composants montés à l arrière pour systèmes combinés basse pression à deux arrivées d air 37030 Trousse de demi masque comprend...

Page 17: ...n pointe en direction opposée du logo 3M situé à l avant du demi masque Fig 2 et 3 2 Tourner de un quart de tour les deux extrémités du tuyau de respiration dans le sens des aiguilles d une montre jusqu à ce qu elles s enclenchent fermement dans les raccords de verrouillage et ne puissent plus tourner Ne pas exercer trop de force en tournant car cela risque d endommager le dispositif de verrouilla...

Page 18: ... la protection respiratoire voulue puis les relier aux baïonnettes extérieures du tuyau de respiration combiné à deux arrivées d air SA 1600 ou SA 2600 3MMC Fig 18 4 Mettre le masque conformément aux procédures énoncées dans la section Mise en place des présentes directives d utilisation 5 Une fois le respirateur adéquatement ajusté effectuer un essai d ajustement par pression positive ou négative...

Page 19: ...établi ou selon l indicateur de fin de durée utile IFDU Remplacer les cartouches immédiatement si l on décèle un goût ou une odeur de contaminant ou si une irritation se manifeste Remplacer les filtres immédiatement s ils sont endommagés encrassés ou si la respiration devient difficile Ne pas utiliser les filtres de série N en présence d aérosols à base d huile Utiliser les filtres de série R pend...

Page 20: ... courroies afin d éliminer les fuites Si l on ne peut obtenir un ajustement parfaitement étanche NE PAS pénétrer dans la zone contaminée Consulter son superviseur REMARQUE Avant de porter un respirateur dans des zones contaminées effectuer un essai d ajustement qualitatif ou quantitatif conformément aux exigences applicables de la norme respiratoire 29 CFR 1910 134 de l OSHA Au Canada se conformer...

Page 21: ...e l eau et un détergent doux AVIS IMPORTANT GARANTIE Si un produit de la Division des produits de protection individuelle de 3M présente un défaut de matériau ou de fabrication ou s il n est pas conforme à toute garantie explicite d adaptation à un usage particulier la seule obligation de 3M qui constitue votre seul recours est au gré de 3M de réparer ou de remplacer toute pièce ou tout produit dé...

Page 22: ...antes sean inmediatamente peligrosas para la vida o salud IDLH Las concentraciones de contaminantes excedan la MUC determinada con el APF para el sistema respirador específico o el APF estipulado por las normas gubernamentales correspondientes lo que sea menor W ADVERTENCIA Los contaminantes peligrosos para su salud incluyen aquellos que no puede ver u oler Abandone el área contaminada de inmediat...

Page 23: ...Aplican las Instrucciones especiales o importantes y o limitaciones de uso específicas Antes del uso del equipo consulte las Instrucciones S Instrucciones especiales o importantes Antes de la instalación de la combinación de Tubos de respiración de línea de aire dual SA 1600 o SA 2600 con filtros o cartuchos retire las válvulas de inhalación del Respirador de pieza facial de cara completa o media ...

Page 24: ...cualquier partícula ya que afectan el desempeño de las válvulas para el control de aire El diagrama Fig 1 del purificador de aire y el equipo regulador de presión muestra lo que se debe instalar en la línea de aire principal antes de la conexión para las mangueras de aire respirable Si se desea usar un filtro de aire pre ensamblado y un dispositivo regulador 3M ofrecer varios filtros paneles regul...

Page 25: ...cial de media cara grande 07026 37032 Kit de pieza facial de cara completa incluye los mismos componentes que el kit 37030 excepto con pieza facial de cara completa mediana 07139 y 1 paquete 25 c u Cubiertas para protector facial 07142 37033 Kit de pieza facial de cara completa incluye los mismos componentes que el kit 37030 excepto con pieza facial de cara completa grande 07140 y 1 paquete 25 c u...

Page 26: ... de 3M en el tubo de respiración y el frente de la pieza facial queden mirando hacia usted Para los Tubos de respiración 3M SA 2500 o SA 2600 asegúrese que el logotipo 3M en el tubo de respiración quede mirando en la dirección opuesta al logotipo 3M en el frente de la pieza facial Fig 12 Gire cada derivación del tubo de respiración un cuarto de vuelta en sentido de las manecillas del reloj hasta q...

Reviews: