93
Table 3: Error Symptoms (continued)
SYMPTOM
CAUSE
ACTION
The laser does
not operate.
The laser is not turned
on.
Laser interlock not
satisfied.
3D equipment interlock
safety rely not satisfied.
Turn the power supply key to the ON position. Verify
that the switch on the laser power supply is ON. Turn
on the laser.
Read error shown on laser power supply. See
Customer Support Hotline on page 99.
Satisfy all safety interlocks or the laser will not
operate. If interlocks cannot be satisfied, see
Customer Support Hotline on page 99.
Elevator, leveler,
or sweeper does
not move.
Loose cables.
Door or resin delivery
module panel interlock
not engaged.
Blown fuse
Bad circuit board or motor
driver.
Secure all connections.
Check that the door/resin delivery module panel
interlocks are operating.
See Customer Support Hotline on page 99.
Try to move using the 3DPrint toolbar. Reboot. See
Customer Support Hotline on page 99.