57
m a n u a l o p e r a t i o n s
Turns:
Defines the amount of resin to be pumped; negative pumps resin into the RDM from
the leveling container; positive pumps resin out of the RDM into the leveling container.
Velocity:
Specifies the pump speed in revolutions per second.
Manual Fill RDM:
This function opens another window.
Note: These indicators apply to all course resin fill systems.
Read all warning messages.
This allows the user to pump resin from the refill
containers into the RDM.
To accomplish this, place the cursor over the
Fill
button and press the left mouse button until the
intended RDM resin level is achieved. If the RDM is
overfilled, manual removal is required.
In some instances, such as after a high volume build,
UP/DOWN:
Adjusts the resin level in the RDM by pumping resin into and out of the leveling
container. To accomplish this, place the cursor over the intended direction. Press and hold
the left mouse button until the desired level is achieved.
Status Indicator:
Notifies user if the machine leveling systems are in range and
functioning correctly.
Green
– All good
Yellow
– Do a systems check
Red
– Manual intervention required (system will not course level).
the resin may be lower than the machine can detect. This function is good for adding resin back to
a level that the machine can detect, and then allow the machine to level properly.
Action:
Describes the current recoater action.
Status:
Displays if the recoater has been reset by sending it to its
Home
location.
Note: If the course level has not been performed first, the leveling bottle can overflow
or continue pumping when empty.
Note: For most resins, 1.5
is the optimal speed.
70696 Revision 1C 27-Aug-08