3D Systems, Inc.
Replacing the Particulate Carbon Filter
The particulate carbon filter is designed to remove particulates, odors, and
gasses from the build area .
The particulate carbon filter will need be checked every 3 months and
replaced if necessary. Access to this filter is from the front of the machine
on the right hand side . Loosen the thumb screw on the door containing the
filter, remove the filter, insert new filter, close door, tighten thumb screw.
NOTE: This is a customer replaceable part . Particulate Filter
with Handle - P/N
310259-00 .
Photo at right illustrates a filter that needs to be changed.
Photo at right illustrates a filter that is clean and new.