3D Systems, Inc.
7
CLEANING AND MAINTENANCE PROCEDURES
INSPECT PLANARIZER PROCEDURE
The planarizer requires no adjustments once it is installed on the printer .The planarizer does require cleaning as part of a preventive
maintenance cycle .
Cleaning the Planarizer Blade
1 . Move print engine to the
Ready
state by selecting
Inspect
Planarizer
under
Tools > Diagnostics
in the UI . This will
place the printer over build plate area and will tilt the blade .
2 . Lift the cover to expose the planarizer blade .
3 . While wearing nitrile gloves, wipe excess material from
the blade using a lint-free cloth, if necessary apply some
isopropyl alcohol to the cloth before wiping .
CAUTION: Blade is sharp, be careful not to cut
yourself when wiping blade .
NOTE: If buildup cannot be cleaned off, or if there are
signs of damage to the blade, it may be necessary
to replace it . See
Replacing Planarizer Blade
for
instructions .
23