Installation Manual
H3C S7500 Series Ethernet Switches
Chapter 1 Product Overview
1-6
(1)
(2)
(3)
(5) (6)
(7) (8) (9)
(14)
(12)
(4)
(10)
(13)
(15)
(11)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(1) SFP port number
(2) SFP port (Gigabit)
(3) Console port
(4) Management Ethernet port
(5) LINK LED of the management Ethernet
port
(6) ACT LED of the management Ethernet
port
(7) RUN LED of LPU
(8) ALM LED of LPU
(9) RUN LED of SRPU
(10) ALM LED of SRPU
(11) Silkscreen
(12) Captive screw
(13) SRPU edge (pink)
(14) RESET button
(15) Ejector lever
(16) OK LED of the power
(17) FAIL LED of the power
(18) OK LED of the fan
(19) FAIL LED of the fan
(20) SFP port status LED
(21) CF card port
(22) Button for ejecting the CF card
Figure 1-5
Panel of a Salience III Series SRPU (LS81SRPG)
Note:
z
The panel of a Salience III Edge SRPU is the same as that of a Salience III SRPU
except the board name and board silk-screen.
z
The panel of a Salience III Plus SRPU is the same as that of a Salience III SRPU
except that it has a different board name and board silk-screen and provides no SFP
port.
1.3.4 Ports
I. CF card port
The port supports standard CF cards. The CF card stores the host version to facilitate
the online software upgrade.