Chapter 13 System Configuration
NetAtlas EPON Manager User’s Guide
162
AAA
This is SNMP authentication trap group related to user’s
authentication. Click All to automatically click all the traps under
this group and click it again to deselect all selected traps. Or click
the specific trap(s) you want to send to the destination.
Auth: This trap is sent when authentication fails due to incorrect
user name and/or password, when the RADIUS server can be
reached or when there is no response message from the RADIUS
server.
Accounting: This trap is sent when when the RADIUS accounting
server can be reached or when there is no response message from
the RADIUS accounting server.
IP
This is SNMP IP trap group related to connectivity test by ping
probe or traceroute test. Click All to automatically click all the traps
under this group and click it again to deselect all selected traps. Or
click the specific trap(s) you want to send to the destination.
Ping: This trap is sent when a single ping probe fails, when a ping
test (consisting of a series of ping probes) fails, or when a ping test
is completed.
Trace Route: This trap is sent when a traceroute test fails. This
trap is sent when a traceroute test is completed.
Switch
This is the SNMP switch trap group related to switch’s STP
(Spanning Tree Protocol), MAC address table, and RMON (Remote
Network Monitoring) in switch. Click All to automatically click all
the traps under this group and click it again to deselect all selected
traps. Or click the specific trap(s) you want to send to the selected
client.
STP: This trap is sent when the STP root switch changes or when
the STP topology changes.
MAC Table: This trap is sent when more than 99% of the MAC
table is used or when less than 95% of the MAC table is used.
RMON: This trap is sent when a variable goes over the RMON
"rising" threshold or when the variable falls below the RMON
"falling" threshold.
Apply
Click Apply to save any changes.
Copy to...
Click the Copy to.. button to copy the configuration from the
device that you are currently configuring to other device(s) of the
same model.
Close
Click Close to exit this screen.
Table 76
System Configuration > Trap Group (continued)
LABEL
DESCRIPTION
Содержание NetAtlas
Страница 2: ......
Страница 8: ...Contents Overview NetAtlas EPON Manager User s Guide 8 ...
Страница 16: ...Table of Contents NetAtlas EPON Manager User s Guide 16 ...
Страница 17: ...17 PART I Introduction Introducing the EMS 19 Main Screen 23 ...
Страница 18: ...18 ...
Страница 42: ...Chapter 2 Main Screen NetAtlas EPON Manager User s Guide 42 ...
Страница 44: ...44 ...
Страница 88: ...Chapter 6 Template NetAtlas EPON Manager User s Guide 88 ...
Страница 98: ...Chapter 7 Provisioning NetAtlas EPON Manager User s Guide 98 ...
Страница 114: ...Chapter 8 Performance NetAtlas EPON Manager User s Guide 114 ...
Страница 148: ...Chapter 11 Tools NetAtlas EPON Manager User s Guide 148 ...
Страница 150: ...150 ...
Страница 152: ...Chapter 12 OLT Configuration Overview NetAtlas EPON Manager User s Guide 152 ...
Страница 198: ...Chapter 14 Switch Configuration NetAtlas EPON Manager User s Guide 198 ...
Страница 216: ...Chapter 15 Multicast Configuration NetAtlas EPON Manager User s Guide 216 ...
Страница 238: ...Chapter 17 RMON Configuration NetAtlas EPON Manager User s Guide 238 ...
Страница 248: ...Chapter 18 EPON Configuration NetAtlas EPON Manager User s Guide 248 ...
Страница 290: ...Chapter 19 EPON Profile Configuration NetAtlas EPON Manager User s Guide 290 ...
Страница 313: ...313 PART IV Appendices and Index Alarm Types and Causes 315 SOAP Schema 317 Legal Information 335 Index 337 ...
Страница 314: ...314 ...
Страница 316: ...Appendix A Alarm Types and Causes NetAtlas EPON Manager User s Guide 316 ...
Страница 334: ...Appendix B SOAP Schema NetAtlas EPON Manager User s Guide 334 ...