User’s Manual 3PH 10KTL-15KTL-V2
Rev. 1.1 15/03/2021
Identification: MD-AL-GI-00
Rev. 1.1 of 15/03/2021 - Application: GID
A1 – Modbus communication address
A2 – RS485 Communication
A3 – Steady light for active RS485 communication
A4 – Wi-Fi Communication
A5 – Flashing light to indicate over-frequency and power derating status. Steady light to indicate remote
control
A6 – Indicates the energy produced today
A7 – Indicates the energy produced in total
A8 – Steady light to indicate high temperature of the inverter
A9 – Output power in real time
A10 - The MPPT SCAN function is on
A11 – Steady light when the input voltage is higher than 160V
A12 – Input channel and input voltage in real time
A13 – Input voltage and current of string 1 and 2, shown alternatively every three seconds
A14 – Light is on when the state is normal
A15 - R/S/T phase voltage, shown alternatively every three seconds
A16 – R/S/T phase current and frequency, shown alternatively every three seconds
A17 – Energy produced from 3:00am to 9:00pm of the same day
When the power is turned on, ZCS INNOVATION…. appears on the screen, as shown in the figure below
when the control board is correctly connected to the communication board, the LCD screen will display the
current status of the inverter, as shown in the figure below.