27 / 130
User’s Manual 3PH 10KTL-15KTL-V2
Rev. 1.1 15/03/2021
Identification: MD-AL-GI-00
Rev. 1.1 of 15/03/2021 - Application: GID
Figure 10 – Removing the polystyrene protections
Figure 11 – Removing the inverter from its packaging
2)
Lift the inverter from its packing box and move it to the installation position.
To prevent damage and personal injury, hold the inverter firmly when moving, as
it is a heavy piece of equipment.
Do not position the inverter with the input/output terminals in contact with
other surfaces, as these are not designed to support the weight of the inverter.
Always position the inverter horizontally.
When placing the inverter on the floor, make sure to place a support under the
unit to protect its front door.
Attention
3.6.
Installing the 3PH 10KTL-15KTL-V2 inverter
1)
Correctly position the mounting bracket on the wall using a level to ensure that it is straight; mark the 6
holes using a suitable marker pen. Keeping the hammer drill perpendicular to the wall and avoiding any
sudden movements when drilling, drill the 6 holes at the points marked on the wall using a 8 mm drill bit.
In case of errors during drilling, it is necessary to reposition the holes.
2)
Insert the plugs horizontally into the holes made, paying attention to the force and depth with which
they are inserted (make sure the plug completely enters the hole).
3)
Align the mounting bracket with the position of the holes and fix it to the wall using the most suitable
screws and flat washers, tightening them properly.