ZXG10-OB06 (V1.0) Integrated Outdoor GSM Base Station Technical Manual
70
Confidential and Proprietary Information of ZTE CORPORATION
B r o a d c a s t I n f o r m a t i o n 1 C h a n g e P r o c e d u r e
Figure 54 shows the broadcast information 1 change procedure.
F
I G U R E
5 4
–
B
R O A D C A S T
I
N F O R M A T I O N
1
C
H A N G E
P
R O C E D U R E
MS
LAPDm
FURRM
HPIMan
LAPD
BSC
PAGCH
M
DL_ DATA_IND (BCCH INFO)
(BCCH INFO)
MPH_
RRC mdToCHP (CHP
SET/STOP BCCH
INFO)
(CHP SET CCCH
Para.)
(SYS INFOTYPE
1/2/ 2bis/2ter/3/4/7/8)
(PAG SET CCCH Para.)
The BSC indicates OB06 that the new system messages (like (RR) System
Information Type 1/2/2bis/2ter 3/4/7/8) will be broadcasted on the BCCH.
When OB06 receives BCCH INFO message, FURRM module sends CHP SET
BCCH INFORMATION message to CHP. If there is any system message,
CHP sends it to MS. If there is no system message, FURRM module sends
CHP STOP BCCH INFORMATION message to CHP. This message indicates
CHP to stop sending these system messages to MS.
For the easy observation system message sending, TRU panel of OB06 has
a signal indicator marked as ‘MOD’.
Following are the different types of system information and their contents:
•
System Information Type 1 contains RACH control parameters and cell
configuration.
•
System Information Type 2 contains RACH control parameters and
BCCH configuration of an adjacent cell.
•
System Information Type 2bis and System Information Type 2ter are
optional messages. They contains BCCH extension configuration of an
adjacent cell.
•
System Information Type 3 contains information of other cells, such as
identifier of a location area and cell identity.
•
System Information Type 4 contains information of control over RACH,
identifier of a location area and cell identity.
•
System Information Type 7 and System Information Type 8 contain
parameters of cell reselection.
FURRM extracts three parameters (BS_PA_MFRMS, BS_AG_BLKS_RES and
CCCH_CONF) from the Control Channel Description information unit of the
System Information Type 3 message. It sends these parameters to CHP
and PAGCHM modules.
Содержание ZXG10-OB06
Страница 4: ...This page is intentionally blank ...
Страница 8: ...This page is intentionally blank ...
Страница 38: ...26 Confidential and Proprietary Information of ZTE CORPORATION This page is intentionally blank ...
Страница 92: ...80 Confidential and Proprietary Information of ZTE CORPORATION This page is intentionally blank ...
Страница 110: ...98 Confidential and Proprietary Information of ZTE CORPORATION This page is intentionally blank ...
Страница 116: ...104 Confidential and Proprietary Information of ZTE CORPORATION This page is intentionally blank ...
Страница 120: ...108 Confidential and Proprietary Information of ZTE CORPORATION This page is intentionally blank ...