![Zte ZXG10 BS21 Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/zte/zxg10-bs21/zxg10-bs21_maintenance-manual_940269080.webp)
ZXG10 BS21 (V2.2) Compact Outdoor BTS for GSM Maintenance Manual
66
Confidential and Proprietary Information of ZTE CORPORATION
T
A B L E
1 2
A
B N O R M A L
S
T A T U S O F
I
N D I C A T O R S O N
E T R M
M
O D U L E
P
A N E L
Name
Description
Color
Abnormal Status
PWR
Power indicator
Green / red
The red indicator is on / an alarm
exists
The red indicator is off / power–off or
other reasons
RUN Running
indicator Green
The red indicator is on or flashes /
system abnormal
MOD
Channel mode
indicator
Green / red
The red indicator is on / BCCH blocked
(blocking on any extBCCH)
ACT
Channel
activation
indicator
Green
The red indicator flashes / channel
blocking indication (SDCCH, TCH…)
The red indicator is on / CU is disabled
STA
Status indicator
Green / red
The red indicator flashes (1Hz) / LAPD
link broken
The red indicator flashes (4Hz) / HDLC
link broken
The red indicator is on / other alarms
related to temperature, clock and
frame number
1.
PWR troubleshooting
When the PWR red indicator is on or is off, check at the background or
LMT whether there are alarms of LAPD link disconnection in FUC and
BSC, communication breakdown between CMM and FUC, and TPU
power failure.
For troubleshooting of LAPD link disconnection in FUC and BSC, refer to
“Disconnected LAPD Link between FUC and BSC”.
For troubleshooting of communication breakdown between CMM and
FUC, refer to “Interrupted Communication between CMM and FUC”.
For troubleshooting of TPU power alarms, refer to “TPU Power Alarm”.
2.
RUN troubleshooting
When the RUN red indicator is on, check at the background or LMT
whether there are alarms of LAPD link disconnection in FUC and BSC,
or communication breakdown between CMM and FUC.
For troubleshooting of LAPD link disconnection in FUC and BSC, refer to
“Disconnected LAPD Link between FUC and BSC”.
For troubleshooting of communication breakdown between CMM and
FUC, refer to “Interrupted Communication between CMM and FUC”.
3.
MOD troubleshooting
When the MOD red indicator is on, it shows that BCCH is blocked. To
solve this problem, unblock the BCCH carrier through dynamic data
management. If it does not work, reset the ETRM module. If the fault
stills exists, replace the ETRM module.
4.
ACT troubleshooting
Содержание ZXG10 BS21