Alarm influence: The output power is abnormal.
Alarm unit location type: CU.
3.
Cause
The PA power amplifier power supply is under-voltage.
4.
Handling method
Check whether the PAS detection circuit is faulty. If so, replace the
ETRM module in time.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.
DLRC_AL Downward Link Check Error
1.
Description
The DLRC_AL downward link has check error.
2.
Related information
Alarm code: 0X1C0E.
Alarm level: 3.
Alarm influence: Massive error codes appear between CHP and the
modulation module, the downward link is faulty, or the ETRM cannot
serve calls normally.
Alarm unit location type: CU.
Internal handling flow: ETRM is disabled.
3.
Cause
There is interference in the link between the CHP and modulation
module.
4.
Handling method
i.
Check the signal and timing between the CHP and modulation
module.
ii.
If the fault persists, the ETRM is faulty. Replace it.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
If the alarm appears transiently, ignore it. If the alarm remains all the
time, handle it immediately.