ZXG10 BS21 (V2.2) Compact Outdoor BTS for GSM Maintenance Manual
118
Confidential and Proprietary Information of ZTE CORPORATION
2.
Related information
Alarm code: 0X1B2B.
Alarm level: 3.
Alarm influence: This ETRM cannot work normally.
Alarm unit location type: FU.
Internal handling flow: Re-download the latest CIP software version.
3.
Cause
The CIP software version is loaded wrongly. If one is configured as
BCCH, the whole cell will be unable to work normally.
4.
Handling method
Reset the ETRM module. If the resetting does not work, replace the
ETRM module.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
This alarm should be handled immediately.
Alarm with Clock between TPU and CMM
1.
Description
Alarm happens with the clock between TPU and CMM.
2.
Related information
Alarm code: 0X1B2C.
Alarm level: 2.
Alarm influence: The FUC cannot work. The cell service will be affected
if the FUC is a BCCH-TPU.
Alarm unit location type: FU.
3.
Cause
The clock between TPU and CMM is interrupted.
4.
Handling method
i.
If only this TPU in the BTS has this alarm, check whether the cables
are connected correctly at the backplane. If so, replace the ETRM
module.
ii.
If other TPUs in the BTS also have this alarm, check whether the
CMM board of the BTS has any clock alarm. If any, replace the CMM.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.