Chapter 3 - Routine Maintenance
Confidential and Proprietary Information of ZTE CORPORATION 63
For troubleshooting of LAPD link broken alarms, refer to “LAPD Long-
Time Link Disconnection”.
For troubleshooting of clock exception alarms, refer to “Clock
Exceptions (13M, FCLK, SYNCLK)”.
5.
STA troubleshooting
i.
If the STA red indicator flashes at a frequency of 1 Hz, it shows
that the LAPD link is broken. For information of troubleshooting of
LAPD link broken alarms, refer to “LAPD Long-Time Link
Disconnection”.
ii.
If the STA red indicator flashes at the frequency of 4 Hz, it shows
that the HDLC link is broken. Check at the background or LMT
whether there are alarms of HW link long-time disconnection,
active / standby rack communication failure, communication link
failure from the standby rack to the active rack, and
communication link failure between the active rack and the left and
right standby racks.
For troubleshooting information of HW link long-time disconnection,
refer to “HW Long Time Link Disconnection”.
For troubleshooting of communication link failure from the standby
rack to the active rack, refer to “Alarms of Communication Link to
Main Rack”.
For troubleshooting of communication link failure between the
active rack and the left and right standby racks, refer to “Alarm
with Communication Link between Master Rack and Left/Right
Slave Rack”.
iii.
When the STA red indicator is on, check at the background or LMT
whether there are alarms about indications of E1 interface sending
forward slip code, E1 interface sending backward slip code, E1
interface receiving forward slip code, and E1 interface receiving
backward slip code.
For troubleshooting of E1 interface sending forward slip code
alarms, refer to “Forward Slip Code Indication at Transmitting End
of E1 Interfaces (A, D and E interfaces)”.
For troubleshooting of E1 interface sending backward slip code
alarms, refer to “Backward Slip Code Indication at Transmitting End
of E1 Interfaces (A, D and E Interfaces)”.
For troubleshooting of E1 interface receiving forward slip code
alarms, refer to “Forward Slip Code Indication at Receiving End of
E1 Interfaces (A, D and E Interfaces)”.
For troubleshooting of E1 interface receiving backward slip code
alarms, refer to “Backward Slip Code Indication at Receiving End of
E1 Interfaces (A, D and E Interfaces)”.
[
Recovery after test
]