ZXG10 BS21 (V2.2) Compact Outdoor BTS for GSM Maintenance Manual
116
Confidential and Proprietary Information of ZTE CORPORATION
TPU’s CIP Initialization Failure
1.
Description
TPU’s CIP initialization fails.
2.
Related information
Alarm code: 0X1B28.
Alarm level: 3.
Alarm influence: The modulation module cannot work, and the carrier
or cell (if the carrier is configured with BCCH) cannot work normally.
Alarm unit location type: FU.
Internal handling flow: RCU is disabled.
3.
Cause
DSP software or hardware is in error.
4.
Handling method
i.
Download the DSP software again.
ii.
Reset the ETRM frame and restart the DSP unit. Check whether the
alarm is recovered. If the alarm is recovered, the DSP initialization
failure is generally caused by strong external interference, and the
ETRM unit can still work normally. If the alarm cannot be recovered,
replace the corresponding ETRM module.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
This alarm should be handled immediately.
CIP Parameter Configuration Error
1.
Description
CIP parameter configuration is wrong.
2.
Related information
Alarm code: 0X1B29.
Alarm level: 3.
Alarm influence: In general, the BSC background validates the data
before the synchronization. This alarm seldom happens because the
data will not be synchronized unless the validity check passes. It will
affect the normal work of the ETRM.
Alarm unit location type: FU
Internal handling flow: Relevant ETRM is disabled; CMM tries to re-
configure the parameters.
3.
Cause
The parameter configuration is wrong or conflicts.