Chapter 2 - Maintenance Overview
Confidential and Proprietary Information of ZTE CORPORATION 15
2.
Indicator status analysis
Indicator status analysis is a frequently adopted method when a fault
is detected by maintenance personnel. With this method, we can locate
and remove faults by observing the indicator status on each board
panel in the rack.
This method requires maintenance personnel to be familiar with the
indicator status and meaning of each board.
3.
Performance analysis
It is implemented through the performance management interface of
the BSS operation & maintenance subsystem OMCR. Through this
interface, maintenance personnel can implement performance
management and signaling tracing on the BSS system.
Through the performance management interface, users can create all
kinds of performance measurement tasks, product various
performance reports and grasp the performance indexes of the BSS
system, such as the traffic of each cell, congestion situation of SDCCH
and TCH, successful and failed switchover. By analyzing such
information, maintenance personnel can discover load allocation
situation in the network in time so as to adjust network parameters to
enhance network performances.
Through the signaling tracing interface, we can trace signaling involved
in BSS (including Gb interface signaling), thus facilitating consulting of
different signaling flows in the debugging and maintenance processes
as well as detecting problems in the signaling cooperation process.
4.
Analyzing with instruments and meters
This method allows maintenance personnel to locate, analyze and
remove faults with the testing mobile, frequency spectrograph,
signaling analyzer, power meter and site master during base station
maintenance.
5.
Plugging and pressing
When detecting a board fault, we can loosen the fixation screw in the
front panel and plug or unplug the board and external interface
connector. In this way, we can remove faults caused by poor contact
or processor faults.
In addition, we can also remove faults caused by poor contact by
pressing the cable connector after power-off.
6.
Comparing and swapping
Comparing indicates to compare a possible faulty board with a board at
the similar position in the system (for example: a board at the same
slot in a multi-module system) from aspects such as the running status,
jumper and connection cables. We can judge whether the board fails
through comparison.
Swapping indicates to replace a possible faulty board with a standby
part or another board of the same type running normally in the system.
We can judge whether the board actually fails according to whether the
fault disappears after board replacement. It should be noted that no
matter the comparison or replacement method is adopted, the board