ZXG10 BS21 (V2.2) Compact Outdoor BTS for GSM Maintenance Manual
124
Confidential and Proprietary Information of ZTE CORPORATION
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.
PA Overheat Major Alarm
1.
Description
PA overheat major alarm happens.
2.
Related information
Alarm code: 0X1C0A.
Alarm level: 3.
Alarm influence: The TRU power output will be shut off protectively,
and the PA ages at a quicker step.
Alarm unit location type: CU.
Internal handling: ETRM is disabled.
3.
Cause
The PA is overheated. Possibly, the PA has worked at full power for a
long time; the fan is not running for a long time; the ambient
temperature is too high; or the detection circuit is faulty.
4.
Handling method
i.
Check whether the fan works normally and whether the ambient
temperature is too high.
ii.
If the fan works normally and the ambient temperature is normal,
but the PA temperature alarm persists, the detection circuit may be
faulty. Replace the ETRM in time.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
This alarm should be handled immediately.
PA Output Power Alarm
1.
Description
PA output power alarm happens.
2.
Related information
Alarm code: 0X1C0B.
Alarm level: 3.
Alarm influence: The ETRM cannot serve calls, or the power control is
out of control.
Alarm unit location type: CU.
3.
Cause