Chapter 6 - Troubleshooting
Confidential and Proprietary Information of ZTE CORPORATION 149
iii.
Check whether there is any alarm information about the clock fault
at the background. If there are 8 K clock alarms or other alarm
information, reset and restart the base station (just by resetting
the CMM module); if this method does not work, modify the clock
synchronization mode of the BS at the background (from internal
synchronization to the external synchronization).
iv.
Use the frequency meter to view whether the frequency difference
the 13 M clock outputs is within the specified range at the front
panel of the BS21 (V2.2) rack. If abnormal, use LMT to calibrate
the clock.
7.
Precautions
Introduce the precautions during troubleshooting of this fault.
Handling Lightning-Stricken BS Faults
1.
Symptom
After thunder storm, the BS breaks down.
2.
Source
Find the fault through the board indicator and the alarms of the
background O&M system.
3.
Related parts
BS power supply, transmission equipment, CMM module and CMM
backplane.
4.
Fault analyzing and locating
The fault is caused by board faults from the lightning strike. Experience
shows that the faults caused by lightning strike include:
i.
Damaged -48 V BS power supply.
ii.
Damaged BS transmission.
iii.
Damaged BS CMM module.
iv.
Damaged CMM backplane.