INSTALLATION AND OPERATING INSTRUCTIONS:
Gripper, electric, GEP5000/GED5000 series
39
DDOC0021
1 / h
EN / 2020-08-15
Zimmer GmbH
•
Im Salmenkopf 5
•
77866 Rheinau, Germany
•
+49 7844 9138 0
•
+49 7844 9138 80
•
www.zimmer-group.com
13. Maintenance
Maintenance-free operation of the gripper is guaranteed for up to
30 million cycles
.
The maintenance interval may shorten under the following circumstances:
• Dirty environment
•
Improper use and use that does not comply with the power specifications.
•
Observe ambient temperature; lubricants harden faster!
Even though the gripper is, as mentioned, maintenance-free, perform a regular visual inspection to check for any corro-
sion, damage or soiling.
We recommend allowing maintenance and seal replacement to be carried out by Zimmer Customer Service.
Dismantling and reassembling the gripper without authorization may result in complications, as special installation
equipment is required in some cases.
Zimmer GmbH shall not be liable in the event of unauthorized dismantling and reassembling of the gripper or in the
event of any malfunction or damage resulting from this.
14. Accessories/scope of delivery
INFORMATION:
If any accessories not sold or authorized by Zimmer GmbH are used, the function of the gripper cannot
be guaranteed.
The accessories from Zimmer GmbH are specifically tailored to the individual gripper.
Please refer to our website for information on corresponding accessories.
15. Transportation/storage/preservation
►
The transport and storage of the gripper must take place exclusively in the original packaging.
►
If the gripper has already been installed on the higher-level machine unit, it must be ensured during transport that
no unintentional movements may take place. Before commissioning the machine after transport, check all power
and communication connections as well as all mechanical connections.
►
If the product is stored for an extended period, the following points are to be observed:
Ö
Keep the storage location as dust-free and dry as possible.
Ö
Avoid temperature fluctuations/observe and adhere to the temperature range.
Ö
Avoid wind/drafts/water condensation formation.
Ö
Package the product.
Ö
During storage, it must be kept from direct sunlight.
►
Clean all components. There must be no soiling left on the components.
►
Visually inspect all of the components.
►
Remove all foreign objects.
►
Properly remove potential corrosion spots.
►
Close electrical connections using suitable covers.
16. Decommissioning and disposal
INFORMATION:
If the gripper reaches the end of its operational phase, the gripper can be completely disassembled and
disposed of. Disconnect the gripper from the power supply completely. The gripper can be disassem-
bled and properly disposed of according to material groups. When disposing of it, observe the locally
applicable environmental regulations and codes and regulations for disposal.