11.2 GEP/GED5000IO error diagnosis
Error code
Error
Possible cause
Measure
1
5
Gripper is ready for operation
No error
-
-
1
5
Motor has slight overcurrent in
multiple consecutively following
cycles
•
Gripper is difficult to move
• Travel path of the gripper is
impeded
• Object being gripped or grip-
per fingers are elastic
►
Check the gripper's freedom
of movement
►
Check the object being
gripped and the gripper
fingers
1
5
Motor has strong excess current
• Gripper is jammed
• Internal error
►
Restore the gripper's freedom
of movement
►
►
Zimmer Customer Service
1
5
Motor has excess current in idle
mode
• Internal error
►
►
Zimmer Customer Service
1
5
Temperature of the motor output
stage above the limit value
• Surrounding temperature too
high
• Gripper is overloaded
► Provide for sufficient ventila
-
tion/cooling
►
Check the object being
gripped and/or the gripper
fingers
1
5
Gripper is in reference run mode • Internal error
►
►
Zimmer Customer Service
1
5
Gripper has no reference on the
jaw position
• Gripper has lost its reference
position
►
►
Zimmer Customer Service
1
5
Motor is in setting run mode at
the end position
• Setting run was started
• CAUTION: do not evaluate the
positions during the setting
run!
►
Wait for completion of the
setting process
1
5
Gripper does not reach the end
position
(Work, teach and base position)
• Gripper does not reach the
work, teach and base position
►
Check the object being
gripped and/or the gripper
fingers