INSTALLATION AND OPERATING INSTRUCTIONS:
Gripper, electric, GEP5000/GED5000 series
17
DDOC0021
1 / h
EN / 2020-08-15
Zimmer GmbH
•
Im Salmenkopf 5
•
77866 Rheinau, Germany
•
+49 7844 9138 0
•
+49 7844 9138 80
•
www.zimmer-group.com
8. Commissioning
8.1 Commissioning the GEP/GED5000IO “Digital”
8.1.1 “Digital” switching sequence
A movement in the desired direction occurs when the corresponding signal is at a high level. After a high level is
detected, the gripper movement occurs until the gripping process ends.
It is important to ensure that, after a gripper movement has taken place, the corresponding signal is reset again
before a signal in the opposite direction is given.
Between withdrawing the signal and the next command, a pause of 10 ms must be observed.
INFORMATION:
Ö
The movement profile only applies to the digital gripper of the GEP/GED5000 series.
0 V
24 V
Imax
≤
5 A
Eingang 1 DIR
Stromaufnahme
Greiferpostion
►◄
◄►