Gripper, electric, GEP5000/GED5000 series
7. Installation
7.1 Safety notes
NOTICE:
Switch off the energy supply for the electronics before any assembly, installation or maintenance work.
►
Electronics may get damaged.
CAUTION:
Switch off the energy supply for the electronics before any assembly, installation or maintenance work.
►
Injuries are possible.
WARNING:
Risk of injury in case of unexpected movement of the machine or system into which the gripper is to be
installed.
► Switch off the power supply to the machine before all work.
►
Secure the machine against being switched on unintentionally.
►
Check the machine for any residual energy.
7.2 Installing the mechanical system
7.2.1 Installing the GEP5000
The gripper must be installed on a mounting surface
in accordance with the flatness specifications.
Length < 100 mm
permitted flatness imperfection
< 0.02 mm
Length > 100 mm
permitted flatness imperfection
< 0.05 mm
Ö
The mounting screws are not included in the
scope of delivery.
Ö
Strength class of the mounting screws ≥ 8.8 (DIN
EN ISO 4762).
Ö
Observe the tightening torque of the mounting
screws.
Ö
Make sure the mounting surface is sufficiently
rigid and flat.
Ö
Use an adapter plate as needed. For information
on adapter plates, please refer to the accessories
list, available on our website.
The gripper can be installed with its base or laterally
onto the mounting piece.
The following work steps must be observed during
installation:
►
Insert the centering sleeves
bm
into the designat-
ed fits on the gripper.
►
Position the gripper on the designated mounting
piece using the centering sleeves
bm
.
►
Use the mounting screws
bl
to secure the grip-
per to the mounting piece.
bm
bl
bm
bm