INSTALLATION AND OPERATING INSTRUCTIONS:
Gripper, electric, GEP5000/GED5000 series
31
DDOC0021
1 / h
EN / 2020-08-15
Zimmer GmbH
•
Im Salmenkopf 5
•
77866 Rheinau, Germany
•
+49 7844 9138 0
•
+49 7844 9138 80
•
www.zimmer-group.com
9.2 GEP/GED5000IO menu cycle procedure
INFORMATION:
Important for handling the gripper!
If no input occurs after three minutes, the gripper exits the menu without saving.
Zimmer Customer Service is available to provide you with assistance if you have any further questions.
• Main menu
►
Press SET for 3 seconds
Ö
The menu display LEDs will flash
• Edit mode
►
Press SET again
Ö
The parameter display LEDs will flash
Ö
Only possible in menus that feature a selection function
►
A value can be changed in a range from 1 to 5 using the arrow keys
• Save the value
►
Press SET
Ö
The value is saved
Ö
The gripper returns to the menu display
Ö
The menu display LEDs will flash
►
You can scroll through the individual menu items using the arrow keys
Ö
Only in the main menu is it possible to exit the menu by pressing SET
Ö
No LEDs will flash