INSTALLATION AND OPERATING INSTRUCTIONS:
Gripper, electric, GEP5000/GED5000 series
11. Error diagnosis
11.1 GEP/GED5000IL error diagnosis
Error code
Error
Possible cause
Measure
0x0000
Gripper is ready for operation
-
-
0x0100
Actuator voltage is too low
• The actuator voltage is not
present
• The applied voltage is too low
►
Ensure improved cooling of
the device
►
Check the gripper's freedom
of movement
►
Choose the selected move-
ment profile
0x0101
Operating voltage is too high
• Ambient temperature of the
gripper is too high
• Gripper overload
•
Incorrect movement profile
selected
►
Ensure improved cooling
►
Check the gripper's freedom
of movement
►
Check the selected movement
profile
0x0102
Operating temperature is too low • Ambient temperature is too low
► Ensure a sufficient operating
temperature
0x0200
IO-Link communication faulty
-
-
0x0201
SPI communication faulty
-
-
0x0300
“ControlWord” implausible
• Multiple bits were set in the
"ControlWord"
►
Only one bit may be set in the
"ControlWord."
0x0301
Positions implausible
•
Transmitted positions (Teach,
Base, Shift, Work) are incorrect
•
Modified process data has not
been taken over
►
Check the transmitted process
data
►
Apply the process data via a
"Handshake"
0x0302
Force value is implausible
• Transmitted force value is not
correct
•
Modified process data has not
been taken over
►
Check the transmitted process
data
►
Apply the process data via a
"Handshake"
0x0303
End speed is not reached
• Voltage supply is too low
• Power resistor is too large
• Gripper is soiled
• Jaw weight is too heavy
► Measure the power resistor (<
1.20 Ohm)
►
Clean the gripper
0x0304
Tolerance value implausible
• Transmitted tolerance value is
not correct
•
Modified process data has not
been taken over
►
Check the transmitted process
data
►
Apply the process data via a
"Handshake"
0x0305
Position measuring system not
referenced
• Gripper has been moved with-
out operating voltage
• Internal error in the position
measuring system
►
Reference the gripper by
means of a "Homing" run