27
11.4.10 StatusWord
StatusWord structure:
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Byte 1
Error
ControlWord
0x0200
ControlWord
0x0100
DataTransferOK
Undefined
-
Position
WorkPo-
sition
TeachPo-
sition
BasePo-
sition
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 2
-
Gripper-
PLCActive
JogWork-
JogBase-
Active -
Movement
-
Complete
InMotion
MotorON
HomingPo
-
sition OK
Bit 0: HomingPosition OK
The product is calibrated at the factory and does not have to be referenced by the customer.
Bit 1: MotorON
The motor of the product switches on automatically when there is a move command. The customer cannot switch it on/off
manually.
Bit 2: InMotion
This bit is active during the run.
Bit 3: MovementComplete
This bit is active after the movement is complete.
Bit 4: JogBaseActive -
Confirmation during the Jog run in the direction of BasePosition.
Bit 5: JogWork
Confirmation during the Jog run in the direction of WorkPosition.
Bit 6: GripperPLCActive
Active as soon as the product has booted up after the cold boot.This bit can be used to verify a “byte swap."
Bit 8: BasePosition
Active if the product is set to BasePosition.
Bit 9: TeachPosition
Active if the product is set to TeachPosition.
Bit 10: WorkPosition
Active if the product is set to WorkPosition.