4. Operation and settings
The user can easily adapt the controller to any
particular job. The system can be commissioned
and operated by either of the following two very
simple methods:
1. Operation through the keyboard and the LCD
display with simple text dialog.
2. Remote operation with a PC and the
ZETAMON software available as an extra.
The parameter menu structure is the same for
both communication methods.
The parameters set can be protected against
unintentional or unauthorized change by means
of a
password
(numbers ranging vom 1 to
9999).
Parameters may only be changed
when the drive is at a standstill.
4.1
Operating through keyboard and LCD display
LCD and the keyboard offer the operator the following direct facilities:
- setting all the parameters required for commissioning
- performing simple measuring and control operations and
- recording the operating states.
Programming is very simple, by means of the three push buttons. The parameters available are divided
into menus according to whether they are belonging together.
The selection of a menu is effected by means of the arrow keys (see figure 4.1).
When pressing the key
[
P
]
, you change to the parameters assigned to the menu.
The selection of a parameter is effected by means of the arrow keys.
When pressing the key
[
P
]
, it is possible to change the parameter using the arrow keys.
When pressing the key
[
P
]
, you return to the parameter selection.
When pressing the key
[↓]
and
[↑]
at the same time, your return to the menu selection.
There are two possibilities in order to change the parameters and two kinds of indication:
Adjustment by putting in a numerical value (in this case: 1,20 m/s).
Adjustment by selecting among possibilities already set (in this case:
ELEVATOR)
Indication by means of "beam spot" representation
Indication by means of "bar" and numerical value representation
Figure 4.2 Examples
change parameter
selection of a menu
selection parameter
P
with
&
P
with
with
Figure 4.1 Function of the keys
ANL ELEVATOR
Installation type
RF RV12 V123 MB
N_IST 1200 min-1
V_3 1.20 m/s
Travel speed
401
Содержание ZETADYN 1DV Series
Страница 2: ...http www bzxindaxin com http www gk world com 全球独家推出 全覆盖型省配线解决方案 ...
Страница 3: ...http www bzxindaxin com http www gk world com ...
Страница 4: ...http www bzxindaxin com http www gk world com ...
Страница 5: ...http www bzxindaxin com http www gk world com ...
Страница 6: ......
Страница 63: ......