42 Commissioning
5.4 Adjustment
Checking the controller reaction
- Control run on several floors
- Observe the indications actual speed, nominal speed and the controller output CO in menu "Monitor".
•
Real and programmed speed have to be the same
•
In direction "Empty Up" with constant run:
CO works in the negative range
•
In direction "Empty Down" with constant run:
CO works in the positive range
•
The pointer CO is not to reach the limits of the range. If it exceeds theses
limits, this is indicated by means of an additional "+" resp "-" character
in the second line.
•
With constant run, the pointer should only slightly move
Checking the distances
In menu "Distances & Times", it is possible to check the accuracy of the disconneting tags set.
Decelerating distance required from V_3 to V_1.
Measured decelerating distance from V_3 to stop.
Measured positioning distance with speed "V_1".
General adjustment references
Figure 5.4: Possibilities to change the curve.
N_REAL 300min-1
N_PROG 300min-1
-............CO.............+
|
Brake Drive
Empty Up Empty Down
S_1 0.05m
Dist. at V1
S_30 1.05m
Dist. V3->0
S_31 1.00m
Dist. V3->V1
V
t
RF
V1
V3
RV1
MB
RV2
V_1
V_3
RB
ACCELERATING
**************
DECELERATING
**************
A_NEG
R_NEG1
R_NEG2
R_POS2
A_POS
R_POS1
S_1
S_DI3
TRAVELLING
**************
Содержание ZETADYN 1DV Series
Страница 2: ...http www bzxindaxin com http www gk world com 全球独家推出 全覆盖型省配线解决方案 ...
Страница 3: ...http www bzxindaxin com http www gk world com ...
Страница 4: ...http www bzxindaxin com http www gk world com ...
Страница 5: ...http www bzxindaxin com http www gk world com ...
Страница 6: ......
Страница 63: ......