Operation and settings 29
4.3.2 The menu "DISTANCES & TIMES"
Contents:
In menu "Distances & Times", measured and calculated
values are indicated.
Total distance driven of the last run
Measured distances at constant speed with "V_1", "V_2" and "V_3".
Total decelerating distances after switching off the driving command
"V_1", "V_2" and "V_3" until the device stops.
Calculated decelerating distance needed from the time of switching off
"V2" resp. "V3" until the positioning speed "V_1" is reached.
Total time driven of the last run.
Measured time from the time the relay "MB" picks up until the first
rotation.
Figure 4.6 Menu "Distances & times"
DIST. & TIMES
**************************
S_GES 0.00 m
Total distance
S_1 0.00 m
Dist. at V_1
S_2 0.00 m
Dist. at V_2
S_3 0.00 m
Dist. at V_3
S_10 0.00 m
Dist. at V_1 -> 0
S_20 0.00 m
Dist. at V2 -> 0
S_30 0.00 m
S_21 0.00 m
Calculated dist. V2->V1
S_31 0.00 m
T_GES 0.0 s
Total travel time
T_MB 0 ms
.
Dist. at V3 -> 0
Calculated dist. V3->V1