12
Enclosure
12.1
Technical data
Type
FTET4AHMQ
FTET6AHMQ
FTET10AHMQ
Part-No.
308131
308132
308133
Rated current output* {1}
[A]
4
6
10
Rated current input {2}
[A]
4,2
6,3
10,8
Max. load limit integral of cut-in current {2}
[A
2
s] 0,6
0,7
1,3
Max. leakage current according to the dened networks
of DIN EN 60990 (depending on connected line voltage)
[mA] 2.5 mA (U
typ
230 V)
3.3 mA (U
max
305 V)
2.6 mA (U
typ
230 V)
3.5 mA (U
max
305 V)
3.0 mA (U
typ
230 V)
4.0 mA (U
max
305 V)
Max. line fuse {3}
[A]
16
16
16
Max. heat dissipation approx. {2}
[W]
65
103
187
Rated temperature
[
°
C] 35
40
50
Weight
[kg]
3.4
5.7
6.8
1
Rated current output
current indication name plate @ rated voltage, @ rated temperature
2
At rated voltage, values for di
ff
erent speci
fi
cations on request
3
Max. supply side line fuse according to EN 60204-1 classi
fi
cation VDE0113 chapter 1
Line voltage*
1 ~ 208...277 V (-10...+10 %), 50/60 Hz
Rated voltage
230 V
Maximal output voltage
1 ~ 270 V
The PFC (Power Factor Controller) makes it mostly independent of the mains voltage.
Maximal output frequency
150 Hz
Power factor
> 0.9
Switching frequency
16 kHz
Voltage supply
e.g. for sensors
+24 V
±
20 %, I
max
120 mA
Power loss in standby mode (switch
position
“
0
”
)
approx. 2.6 W
Output A1: 0 - 10 V
Output A2: 0 - 10 V
I
max
per 6 mA (short-circuit-proof)
Max. contact rating of the internal relay 2 A / 250 V AC
Max. permissible ambient temperature 55
°
C
Min. permissible ambient temperature 0
°
C (if mains voltage is not switched o
ff
up to -20
°
C)
Permissible installation height
0...4000 m amsl
≤
1000 m: no limitation
> 1000 m: max. permissible output current = current indication name plate minus 5 % /
1000 m
> 2000 m: max. permissible line voltage = max. voltage indication name plate minus
1.29 % / 100 m
Permissible rel. humidity
85 % no condensation
Electromagnetic compatibility for the
standard voltage 230 / 400 V accord-
ing to DIN IEC 60038
Interference emission EN IEC 61000-6-3 (domestic household applications)
Interference immunity EN IEC 661000-6-2 (industrial applications)
Harmonics current
Active power factor adjustment for sinusoidal input current (PFC = Power Factor
controller), harmonic current in accordance with EN 61000-3-2 are guaranteed
Vibratory strength
(for vertical installation, i.e. cable inlet
down).
Broadband noise (simulated life-endurance test) in accordance with EN 61373, cat-
egory 1 class B.
Shock test according to EN 61373, category 1
Housing protection
IP 54
*
Regarding the mains connection, the Fcontrol devices are to be classi
fi
ed as category
“
C2
”
devices according to the relevant
DIN EN 61800-3. The increased requirements placed on electrical interference > 2 kHz for category
“
C1
”
devices are
complied with in addition.
Operating Instructions
Fcontrol
–
model series FTET4/6/10AHMQ
Enclosure
L-BAL-E094-GB 2022/47 Index 007
Part.-No.
41/46