Axioskop 2 FS
plus
INSTRUMENT DESCRIPTION
Axioskop 2 FS
MOT
Technical data
Carl Zeiss
B 40-076 e 02/01
1-17
Separate 12 V DC 100 W power unit, stabilized
Operation........................................................................................................................... closed rooms
Protection class.......................................................................................................................................I
Enclosure protection ........................................................................................................................IP 20
Line voltage ............................................................................................................100 to 240 V ±10 %
Change of line voltage is not required!
Line frequency ..................................................................................................................... 50 to 60 Hz
Power consumption when HAL 100 is used................................................................................. 100 VA
HBO 100 W transformer (HBO 100 W/2 and HBO 103 W/2)
Operation........................................................................................................................... closed rooms
Protection class.......................................................................................................................................I
Enclosure protection ........................................................................................................................IP 20
Line voltage can be changed between.................................................................. 115 VAC and 230 VAC
Line frequency...................................................................................................................... 50 to 60 Hz
Power consumption when HBO 103 is used ................................................................................. 265 VA
Fuses in accordance with IEC 127
Separate 12 V DC 100 W power unit .......................................................................... T 4 A/H, 5x20 mm
HBO 100 W transformer .........................................................................................T 3.15 A/H, 5x20 mm
Light sources
Halogen illuminator .....................................................................................................HAL 12 V / 100 W
Adjustment of the light source ..................................................................... continuous, 3 to 12 V
Mercury pressure short-arc lamp ........................................................................................ HBO 103 W/2
Power consumption for HBO 103 W/2 ................................................................................. 103 W
Содержание Axioskop 2 FS plus
Страница 1: ...Operating Manual Axioskop 2 FS plus FS MOT Research Microscope...
Страница 14: ...INTRODUCTION Axioskop 2 FS plus Carl Zeiss Axioskop 2 FS MOT 0 14 B 40 076 e 02 01...
Страница 36: ...START UP Axioskop 2 FS plus Carl Zeiss List of illustrations Axioskop 2 FS MOT 2 4 B 40 076 e 02 01...
Страница 110: ...OPERATION Axioskop 2 FS plus Carl Zeiss Axioskop 2 FS MOT 3 40 B 40 076 e 02 01...
Страница 112: ...CARE MAINTENANCE TROUBLESHOOTING Axioskop 2 FS plus Carl Zeiss Axioskop 2 FS MOT 4 2 B 40 076 e 02 01...
Страница 122: ...ANNEX Axioskop 2 FS plus Carl Zeiss Axioskop 2 FS MOT A 2 B 40 076 e 02 01...