16) BRAKE SWITCH
The level of the Pedal Brake Microswitch.
-
ON / +VB = active entry of Brake pedal Microswitch.
-
OFF / GND = non active entry of microswitch.
17) EXCLUSIVE HYDRO
Status of the exclusive hydro input.
-
ON / +VB = active entry of closed switch.
-
OFF / GND = non active entry of open switch.
18) BRAKEPEDAL POT.
The percentage of the pressure on the brake pedal (100% if the pedal is
totally pressed, 0% if the pedal is released).
19) HAND BRAKE
The level of the Handbrake Microswitch.
-
ON / GND = active entry of Handbrake Switch (open switch).
-
OFF/ +VB = non active entry of microswitch (closed switch).
20) VOLTAGE BOOSTER
This is the booster of the voltage supplied to the motor in load condition; it is
expressed in a percentage of the full voltage.
21) BATTERY VOLTAGE
Level of battery voltage measured at the input to the key switch.
22) BATTERY CHARGE
The percentage Charge level of the battery.
5.11 Tester: description of the function; Pump configuration
The most important input or output signals can be measured in real time using
the TESTER function of the console. The Console acts as a multimeter able to
read voltage, current and temperature. The following definition listing shows the
relative measurements:
1) MOTOR
VOLTAGE
This is the voltage supplied to the motor by the inverter; it is expressed as a
percentage of the full voltage (which depends of the battery voltage).
2) FREQUENCY
This is the frequency of the voltage and current supplied to the motor.
3) ENCODER
This is the speed of the motor, expressed in the same unit of the frequency;
this information comes from the speed sensor.
4) SLIP
VALUE
This is the difference of speed between the rotating field and the shaft of the
motor, expressed in the same unit of the frequency.
5) CURRENT
RMS
Root Mean Square value of the motor current.
6) TEMPERATURE
The temperature measured on the aluminium heat sink holding the MOSFET
devices.
7) MOTOR
TEMPERATURE
This is the temperature of the motor; if the option is programmed "None" (see
chapter 5.4.2) it shows 0°.
8) ACCELERATOR
The voltage of the accelerator potentiometer's wiper (CPOT). The voltage
level is shown on the Left Hand Side of the Console Display and the value in
percentage is shown on the Right Hand Side.
ADEZP0AE - AC-2 INVERTER - User Manual
Page - 45/64
Содержание AC-2
Страница 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Страница 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Страница 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 49: ...12 Press OUT to return to the Opening Zapi Display ADEZP0AE AC 2 INVERTER User Manual Page 49 64...