encoder (Hz)
encoder (Hz)
slip value (Hz)
slip value (Hz)
current rms (A)
current rms (A)
temperature (°C)
temperature (°C)
motor temperat. (°C)
motor temperature (°C)
accelerator (V)
accelerator (V)
forward switch (ON/OFF)
lifting switch (ON/OFF)
backward switch (ON/OFF)
1st speed switch (ON/OFF)
enable switch (ON/OFF)
2nd speed switch (ON/OFF)
seat switch (ON/OFF)
3rd speed switch (ON/OFF)
backing f. (ON/OFF)
4th speed switch (ON/OFF)
backing b. (ON/OFF)
hydro speed req. (ON/OFF)
cutback switch (ON/OFF)
cutback switch (ON/OFF)
brake switch (ON/OFF)
voltage booster (%)
exclusive hydro (ON/OFF)
battery voltage (V)
brakepedal pot. (%)
battery charge (%)
hand brake (ON/OFF)
voltage booster (%)
battery voltage (V)
battery charge (%)
-
Save function (for storing data).
-
Restore function (for loading parameters on another inverter).
-
Display of the last 5 alarms including hour-meter value and temperature at
the moment of the alarm.
-
Accelerator range programming: records the minimum and maximum useful
accelerator stroke values for both direction of running.
-
See the console manual for a detailed description of function and
parameters.
5.8 Sequence for Ac Inverter Traction setting
When the "Key Switch" is closed, if no alarms or errors are present, the Console
Display will be showing the Standard Zapi Opening Display.
If the controller is not configured to your requirements, follow the sequence
detailed on Chapter 6.2. Remember to re-cycle the Key Switch if you make any
changes to the controller’s configuration. Otherwise follow the sequence detailed
below:
1)
Select the Options required. See Chapter 5.1 ÷ 5.4.
2)
Select and set the Battery Voltage. See Chapter 5.4.
3)
Confirm correct installation of all wires. Use the Console’s TESTER function
to assist.
4)
Perform the accelerator signal acquisition procedure using the Console
“PROGRAM VACC”. Procedure is detailed on Chapter 6.4.
5)
Set the "MAXIMUM CURRENT” Current, using the table on Chapter 5.5, 5.6.
6)
Set the Acceleration Delay requirements for the machine. Test the
parameters in both directions.
7)
Set the FREQUENCY CREEP level starting from level 0.6Hz. The machine
should just move when the accelerator microswitch is closed. Increase the
Level accordingly.
8)
Set the Speed Reductions as required. Make adjustments to “CUTBACK
SPEED” Check the performance with the accelerator pedal totally depressed.
Page - 42/64
ADEZP0AE - AC-2 INVERTER - User Manual
Содержание AC-2
Страница 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Страница 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Страница 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 49: ...12 Press OUT to return to the Opening Zapi Display ADEZP0AE AC 2 INVERTER User Manual Page 49 64...