read voltage, current and temperature. The following definition listing shows the
relative measurements:
1) MOTOR
VOLTAGE
This is the voltage supplied to the motor by the inverter; it is expressed as a
percentage of the full voltage (which depends of the battery voltage).
2) FREQUENCY
This is the frequency of the voltage and current supplied to the motor.
3) ENCODER
This is the speed of the motor, expressed in the same unit of the frequency;
this information comes from the speed sensor.
4) SLIP
VALUE
This is the difference of speed between the rotating field and the shaft of the
motor, expressed in the same unit of the frequency.
5) CURRENT
RMS
Root Mean Square value of the motor current.
6) TEMPERATURE
The temperature measured on the aluminium heat sink holding the MOSFET
devices.
7) MOTOR
TEMPERAT.
This is the temperature of the motor; if the option is programmed "None" (see
chapter 5.4.1) it shows 0°.
8) ACCELERATOR
The voltage of the accelerator potentiometer's wiper (CPOT). The voltage
level is shown on the Left Hand Side of the Console Display and the value in
percentage is shown on the Right Hand Side.
9) FORWARD
SWITCH
The level of the Forward direction digital entry FW.
-
ON / +VB = active entry of closed switch.
-
OFF / GND = non active entry of open switch.
10) BACKWARD SWITCH
The level of the Reverse direction digital entry BW.
-
ON / +VB = active entry of closed switch.
-
OFF / GND = non active entry of open switch.
11) ENABLE SWITCH
Status of the accelerator enable input.
-
ON / +VB = active entry of closed switch.
-
OFF / GND = non active entry of open switch.
12) SEAT SWITCH
The level of the Seat Microswitch digital entry.
-
ON / +VB = active entry of closed switch.
-
OFF / GND = non active entry of open switch.
13) BACKING F.
Status of the inching function (forward direction) input.
-
ON / +VB = active entry of closed switch.
-
OFF / GND = non active entry of open switch.
14) BACKING B.
Status of the inching function (backward direction) input.
-
ON / +VB = active entry of closed switch.
-
OFF / GND = non active entry of open switch.
15) CUTBACK SWITCH
The level of the Speed Reduction Microswitch.
-
ON / GND = active entry of speed reduction microswitch.
-
OFF / +VB = non active entry of microswitch.
Page - 44/64
ADEZP0AE - AC-2 INVERTER - User Manual
Содержание AC-2
Страница 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Страница 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Страница 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 49: ...12 Press OUT to return to the Opening Zapi Display ADEZP0AE AC 2 INVERTER User Manual Page 49 64...