PROGRAMMED LEVEL
PARAMETER UNIT
0 1 2 3 4 5 6 7 8 9
ACCELERATION DELAY (*)
Sec.
2.5
3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
RELEASE BRAKING (**)
Sec.
5.5
5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0
INVERS.
BRAKING
(**)
Sec.
5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0
PEDAL
BRAKING
(**)
Sec.
5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0
SPEED
LIMIT
BRK.
(**)
Sec.
8.9 8.3 7.7 7.1 6.6 6.0 5.5 4.9 4.4 3.8
BRAKE
CUTBACK
(**)
Sec.
5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0
MAX
SPEED
FORW
Hz
65 80 95 110 125 140 155 170 185 200
MAX
SPEED
BACK
Hz
65 80 95 110 125 140 155 170 185 200
CUTBACK
SPEED
%Max
Sp 10 20 30 40 50 60 70 80 90 100
CURVE
CUTBACK
%Max
Sp 0 10 21 33 44 55 66 78 89 100
FREQUENCY
CREEP
Hz
0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0
MAXIMUM
CURRENT
%IMAX 47 53 58 64 70 76 82 88 94 100
BACKING
SPEED
Hz
0 2 4 6 8 10 12 14 16 18
BACKING
TIME
Sec. 0.
2
0.5 1.0 1.4 1.8 2.3 2.7 3.1 3.6 4.0
AUXILIARY
TIME
Sec.
0 1 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5
(*)
The acceleration time shown is the time from 0 Hz to 100 Hz. This is the
ideal ramp calculated by the software; the real ramp could change as a
function of motor control parameter setting and, obviously, as a function
of the load.
(**)
The braking feature is based upon deceleration ramps. The value shown
in the table is the time to decrease the speed from 100 Hz to 0 Hz. This
is the ideal ramps calculated by the software; the real ramp could
change as a function of motor control parameter setting and, obviously,
as a function of the load.
After changing a parameter, press ENTER to confirm data when requested by
the message on the console. Parameters modified and optimized on one unit can
be stored by the console (SAVE) and then released (RESTORE) on another
inverter, thus allowing fast and standardized settings (see console manual for
details).
5.6 Parameter regulation: Pump configuration
The following parameters can be modified:
1) ACCELER.
DELAY
Acceleration ramp.
2) DECELER.
DELAY
Deceleration ramp.
3) MAX
SPEED
UP
It determines the maximum lifting speed with a potentiometer control.
4) MIN SPEED UP
It determines the minimum lifting speed with a potentiometer control
when
the lifting enable switch is closed.
ADEZP0AE - AC-2 INVERTER - User Manual
Page - 39/64
Содержание AC-2
Страница 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Страница 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Страница 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 49: ...12 Press OUT to return to the Opening Zapi Display ADEZP0AE AC 2 INVERTER User Manual Page 49 64...