2 SPECIFICATION
2.1 Technical specifications
Inverter for AC asynchronous 3-phase motors
Regenerative braking functions
Can-bus interface
Digital control based upon a microcontroller
Voltage:....................................................................... 24 - 36 - 48 - 72 – 80 – 96 V
Maximum current (24 V, 36 V): .................................................. 450 A (RMS) for 3'
Maximum current (36 V, 48 V): .................................................. 350 A (RMS) for 3'
Maximum current (72 V, 80 V): .................................................. 275 A (RMS) for 3'
Maximum current (96 V): ........................................................... 250 A (RMS) for 3'
Booster (all version) ..........................10% of maximum current for some seconds;
Operating frequency: ......................................................................................8 kHz
External temperature range: .............................................................-30 °C ÷ 40 °C
Maximum inverter temperature (at full power): ............................................... 75 °C
2.2 Block diagram
2.3 Control unit
2.3.1 Microswitches
-
The microswitches must have a contact resistance lower than 0.1
Ω
and a
leakage current lower than 100 µA.
-
When full load connected, the voltage drop between the key switch contacts
must be lower than 0.1 V.
-
The microswitches send a voltage signal to the microprocessor when a
Page - 6/64
ADEZP0AE - AC-2 INVERTER - User Manual
Содержание AC-2
Страница 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Страница 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Страница 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 49: ...12 Press OUT to return to the Opening Zapi Display ADEZP0AE AC 2 INVERTER User Manual Page 49 64...