10 PERIODIC MAINTENANCE TO BE
REPEATED AT TIMES INDICATED
Check the wear and condition of the Contactors’ moving and fixed contacts.
Electrical Contacts should be checked every
3 months.
Check the Foot pedal or Tiller microswitch. Using a suitable test meter, confirm
that there is no electrical resistance between the contacts by measuring the volt
drop between the terminals. Switches should operate with a firm click sound.
Microswitches should be checked every
3 months.
Check the Battery cables, cables to the inverter, and cables to the motor. Ensure
the insulation is sound and the connections are tight.
Cables should be checked every
3 months.
Check the mechanical operation of the pedal or tiller. Are the return springs ok.
Do the potentiometers wind up to their full or programmed level.
Check every
3 months.
Check the mechanical operation of the Contactor(s). Moving contacts should be
free to move without restriction.
Check every
3 months.
Checks should be carried out by qualified personnel and any replacement parts
used should be original. Beware of NON ORIGINAL PARTS.
The installation of this electronic controller should be made according to the
diagrams included in this Manual. Any variations or special requirements should
be made after consulting a Zapi Agent. The supplier is not responsible for any
problem that arises from wiring methods that differ from information included in
this Manual.
During periodic checks, if a technician finds any situation that could cause
damage or compromise safety, the matter should be bought to the attention of a
Zapi Agent immediately. The Agent will then take the decision regarding
operational safety of the machine.
Remember that Battery Powered Machines feel no pain.
NEVER USE A VEHICLE WITH A FAULTY ELECTRONIC CONTROLLER.
Page - 64/64
ADEZP0AE - AC-2 INVERTER - User Manual
Содержание AC-2
Страница 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Страница 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Страница 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 49: ...12 Press OUT to return to the Opening Zapi Display ADEZP0AE AC 2 INVERTER User Manual Page 49 64...