5) CUTBACK
SPEED
Speed reduction when the cutback switch is active.
6) 1ST SPEED FINE
First speed, fine regulation.
7) 2ND SPEED FINE
Second speed, fine regulation.
8) 3RD SPEED FINE
Third speed, fine regulation.
9) 4TH SPEED FINE
Fourth speed, fine regulation.
10) HYD SPEED FINE
Hydro speed, fine regulation.
11) MAXIMUM CURRENT
The maximum current of the inverter.
12) AUXILIARY TIME
Time delay when an hydraulic steering function request is switched off.
The following table shows the different values at which the parameters can be
set.
PROGRAMMED LEVEL
PARAMETER UNIT
0 1 2 3 4 5 6 7 8 9
ACCELER. DELAY (*)
Sec.
0.5 0.7 1.0 1.4 1.9 2.5 3.2 4.0 4.8 5.5
DECELER. DELAY (**)
Sec.
0.5 0.7 1.0 1.4 1.9 2.5 3.2 4.0 4.8 5.5
MAX
SPEED
UP
Hz
65 80 95 110 125 140 155 170 185 200
MIN SPEED UP
Hz
0
13.5 15.0
16.5
18.0
19.5
21.0 22.5 24.0
25.5
CUTBACK
SPEED
%Max
Sp 10 20 30 40 50 60 70 80 90 100
SPEED
FINE
(ALL)
(***)
Hz - - - - - - - - - -
MAXIMUM
CURRENT
%IMAX 47 53 58 64 70 76 82 88 94 100
AUXILIARY
TIME
Sec.
0 0.2 0.4 0.8 1.0 1.5 2.0 3.0 4.0 5.0
(*)
The acceleration time shown is the time from 0 Hz to 100 Hz (maximum
selectable speed). This is the ideal ramp calculated by the software; the
real ramp could change as a function of motor control parameter setting
and, obviously, as a function of the load.
(**)
The deceleration time shown in the table is the time from 100 Hz to 0
Hz. This is the ideal ramp calculated by the software; the real ramp
could change as a function of motor control parameter setting and,
obviously, as a function of the load.
(***)
Adjustable with a 1 Hz resolution in the 0 to 200 Hz range.
After changing a parameter, press ENTER to confirm data when requested by
the message on the console. Parameters modified and optimized on one unit can
be stored by the console (SAVE) and then released (RESTORE) on another
inverter, thus allowing fast and standardized settings (see console manual for
details).
Page - 40/64
ADEZP0AE - AC-2 INVERTER - User Manual
Содержание AC-2
Страница 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Страница 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Страница 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 49: ...12 Press OUT to return to the Opening Zapi Display ADEZP0AE AC 2 INVERTER User Manual Page 49 64...