OFF: the battery discharge level check is carried out but no alarm is
signalled.
Very important:
In the combi system (pump + traction), the battery discharge calculation for
the complete system is carried out by the traction inverter; the information
about the pump inverter consumption is sent on the can-bus line from the
pump inverter to the traction inverter. So the correct programming for the
"Battery check" option is :
- traction
inverter:
ON
- pump
inverter: OFF.
3) SET
TEMPERATURE
-
DIGITAL:
a digital (ON/OFF) motor thermal sensor is connected to F6
input.
-
ANALOG: an analog motor thermal sensor is connected between F6
and F12 (the curve can be customized on a customer request).
-
NONE:
no motor thermal sensor switch is connected.
SUBMENU "ADJUSTMENTS"
1) SET BATTERY TYPE
It selects the nominal battery voltage.
2) ADJUST
BATTERY
Fine adjustment of the battery voltage measured by the controller.
3) THROTTLE 0 ZONE
It establishes a deadband in the accelerator input curve (see also curve
below).
4) THROTTLE X POINT
This parameter changes the characteristic of the accelerator input curve.
5) THROTTLE Y POINT
This parameter changes the characteristic of the accelerator input curve.
VACC MIN and VACC MAX are values programmable by the "Program
Vacc" function.
6) ADJUSTMENT
#04
This parameter determines the motor temperature level at which the “Motor
temperature” alarm is signalled. The range is from 70 °C to 160 °C with 10 °C
steps. This parameter must be adjusted only if the “Set temperature” (menu
Page - 32/64
ADEZP0AE - AC-2 INVERTER - User Manual
Содержание AC-2
Страница 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Страница 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Страница 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 49: ...12 Press OUT to return to the Opening Zapi Display ADEZP0AE AC 2 INVERTER User Manual Page 49 64...