YSI 5200A
253
YSI 5200A
252
Menu Maps
FeedSmart
tm
Timer
1
(Disabled)
Feed
Timer
(Disabled)
FCR
(Disabled)
Biomass
(0
oz)
1 to 100000
Feed
%
Biomass
(0.00%)
0.01–99.90%
Daily
Weight
(0
oz)
1
to 100000
FCR
Factor
(0.03%)
0.01 to 100.00
Feeder
Feed
Mode
Timed
Continuous
Daily
Weight
(0
oz)
1 to 100000
Daily
Feedings
(3)
1‐255
Start
Date
(01/01/2007)
Year
(2007)
2007‐2099
Month
(January)
Jan
‐
Dec
Day
(1)
1‐31
Run
Screen
→
Menus
→
Timers
→
FeedSmart
Timer 1
1‐31
Start
Time
(12:00:00
AM)
Hours
(12)
1‐12
Minutes
(0)
1‐59
Seconds
(0)
1‐59
Mode
(AM)
AM
PM
End
Date
(01/01/2007)
Year
(2007)
2007‐2099
Month
(January)
Jan
‐
Dec
Day
(1)
1‐31
End
Time
(12:00:00
AM)
Hours
(12)
1‐12
Minutes
(0)
1‐59
Seconds
(0)
1‐59
Mode
(AM)
AM
AM
PM
Sun
‐
Sat
(Disabled)
Sensors(Disabled)
Sensors
(Disabled)
DO
Low
(0.00
mg/l)
0 to 60.00
DO
High
(0.00
mg/l)
0 to 60.00
DO
Change
(0.01%)
0.00 to 9.9%
Temp
Low
(0.0
c)
1c to 44.0 c
Temp
High
(0.0
c)
1c
to
44.0
c
Temp
Change
(0.01%)
0.00
to
9.9%
Relay
(Disabled)
Feed
Smart
Timer
(Disabled)
Instrument
(Instrument)
Device
Address
Local
Machine
Master
Slave
1
‐
31
Relay
(Unassigned)
Relay
1
‐
8
Units (oz)
Units
(oz)
oz
g
lb
kg
Calibrate
(180)
(0
oz)
Feed
Timer
Test
Run
Time
Feed
Timer
Test
Weight
Appendix 4 - Declaration of Conformity
The undersigned hereby declares on behalf of the named manufacturer under our sole
responsibility that the listed product conforms to the requirements for the listed European
Council Directive(s) and carries the CE mark accordingly.
Manufacturer:
YSI Incorporated
1725 Brannum Lane
Yellow Springs, OH 45387
USA
Product Name:
5200A
Model Numbers
Instrument/Accessory:
5200A
Conforms to the following:
Directives:
EMC 2004/108/EC
RoHS 2011/65/EU
WEEE 2002/96/EC
LVD 2006/95/EC
Harmonized Standards:
• EN61326-1:2006, Electrical equipment for
measurement, control, and laboratory use – EMC
requirements – Part 1: General Requirements
• EN61326-2-3:2006, Electrical equipment for
measurement, control and laboratory use – EMC
requirements – Part 2-3: Particular Requirements
– Test configuration, operational conditions,
and performance criteria for transducers with
integrated or remote signal conditioning.
• EN61000-3-2:2006+A1:2009+A2:2009,
Electromagnetic compatibility (EMC) – Part 3-2:
Limits – Limits for harmonic current emissions
(equipment input current < 16A per phase).
• EN61000-3-3:2008, Electromagnetic compatibility
(EMC) – Part 3-3: Limits – Limitation of voltage changes,
voltage fluctuations and flicker in public low-voltage
supply systems, for equipment with rated current < 16A
per phase and not subject to conditional connection..
• IEC61010-1:2010
Declaration of Conformity