5-79
IM 760101-11E
Commands
5
:STORe:NUMeric:NORMal:<Normal
measurement function>
Function
Turns ON/OFF the output of the function when
storing the numerical data during normal
measurement or queries the current setting.
Syntax
:STORe:NUMeric:NORMal:<Normal
measurement function> {<Boolean>}
:STORe:NUMeric:NORMal:<Normal
measurement function>?
<Normal measurement function> =
{URMS|
UMN|UDC|UAC|IRMS|...}
(See the function
selection list (1) of “DISPlay group.”)
Example
:STORE:NUMERIC:NORMAL:URMS ON
:STORE:NUMERIC:NORMAL:URMS? ->
:STORE:NUMERIC:NORMAL:URMS 1
:STORe:RECall
Function
Sets the data number to be recalled or queries
the current setting.
Syntax
:STORe:RECall {<NRf>}
:STORe:RECall?
<NRf> = 1 to 999999
Example
:STORE:RECALL 1
:STORE:RECALL? -> :STORE:RECALL 1
:STORe:RTIMe?
Function
Queries the store start and stop date/time for
real-time store mode.
Syntax
:STORe:RTIMe?
Example
:STORE:RTIME? -> :STORE:RTIME:
START 2001,1,1,0,0,0;
END 2001,1,1,1,0,0
:STORe:RTIMe:{STARt|END}
Function
Sets the store {start|stop} date/time for real-time
store mode or queries the current setting.
Syntax
:STORe:RTIMe:{STARt|END} {<NRf>,
<NRf>,<NRf>,<NRf>,<NRf>,<NRf>}
:STORe:RTIMe:{STARt|END}?
{<NRf>, <NRf>, <NRf>, <NRf>, <NRf>, <NRf>}
= 2001, 1, 1, 0, 0, 0 to 2099, 12, 31, 23, 59, 59
1st <NRf> = 2001 to 2099 (year)
2nd <NRf> = 1 to 12
(month)
3rd <NRf> = 1 to 31
(day)
4th <NRf> = 0 to 23
(hour)
5th <NRf> = 0 to 59
(minute)
6th <NRf> = 0 to 59
(second)
Example
:STORE:RTIME:START 2001,1,1,0,0,0
:STORE:RTIME:START? -> :STORE:
RTIME:START 2001,1,1,0,0,0
:STORe:SMODe
Function
Sets the store mode or queries the current
setting.
Syntax
:STORe:SMODe {MANual|RTIMe|
INTEGrate}
:STORe:SMODe?
MANual = Manual store mode
RTIMe = Real-time store mode
INTEGrate = Integration synchronization store
mode
Example
:STORE:SMODE MANUAL
:STORE:SMODE? -> :STORE:
SMODE MANUAL
:STORe:STARt
Function
Starts the data store operation.
Syntax
:STORe:STARt
Example
:STORE:START
Description When “
:STORe:SMODe
” is set to MANual, the
store operation is executed. When set to
{RTIMe|INTEGrate}
the WT1600 enters the
store wait state.
:STORe:STOP
Function
Stops the data store operation.
Syntax
:STORe:STOP
Example
:STORE:STOP
:STORe:WAVE?
Function
Queries all settings related to the storage of
waveform display data.
Syntax
:STORe:WAVE?
Example
:STORE:WAVE? -> :STORE:WAVE:U1 1;
U2 0;U3 0;U4 0;U5 0;U6 0;I1 1;I2 0;
I3 0;I4 0;I5 0;I6 0
:STORe:WAVE:ALL
Function
Collectively turns ON/OFF the output of all
waveforms when storing waveform display data.
Syntax
:STORe:WAVE:ALL {<Boolean>}
Example
:STORE:WAVE:ALL ON
:STORe:WAVE:{U<x>|I<x>|SPEed|TORQue}
Function
Turns ON/OFF the output of the waveform when
storing the waveform display data or queries the
current setting.
Syntax
:STORe:WAVE:{U<x>|I<x>|SPEed|
TORQue} {<Boolean>}
:STORe:WAVE:{U<x>|I<x>|SPEed|
TORQue}?
<x> = 1 to 6
Example
:STORE:WAVE:U1 ON
:STORE:WAVE:U1? -> :STORE:WAVE:U1 1
Description
{SPEed|TORQue}
is valid only when the motor
evaluation function (/MTR option) is installed.
5.18 STORe Group
Содержание wt1600
Страница 1: ...Digital Power Meter Communication Interface IM 760101 11E 4th Edition ...
Страница 131: ...7 2 IM 760101 11E 7 2 Sample Program Image ...
Страница 138: ...Sample Program 7 9 IM 760101 11E 7 7 4 Output of Normal Measurement Data ...
Страница 142: ...Sample Program 7 13 IM 760101 11E 7 7 5 Output of Harmonic Measurement Data ...