Commands
5-1
IM 760101-11E
5
5.1
Command List
Command
Function
Page
AOUTput Group
:AOUTput?
Queries all settings related to the D/A output.
5-12
:AOUTput:HARMonics?
Queries all settings related to the D/A output for harmonic measurement.
5-12
:AOUTput:HARMonics:CHANnel<x>
Sets the D/A output items for harmonic measurement or queries the current
setting.
5-12
:AOUTput:NORMal?
Queries all settings related to the D/A output for normal measurement.
5-13
:AOUTput[:NORMal]:CHANnel<x>
Sets the D/A output items for normal measurement or queries the current
setting.
5-13
:AOUTput[:NORMal]:IRTime
Sets the rated time of D/A output for integration for harmonic measurement
or queries the current setting.
5-13
COMMunicate Group
:COMMunicate?
Queries all settings related to communications.
5-14
:COMMunicate:HEADer
Sets whether or not to be added a header to the response to a query or
queries the current setting.
5-14
:COMMunicate:LOCKout
Sets or clears local lockout.
5-14
:COMMunicate:OPSE
Sets the overlap command that is to used by the
*OPC
,
*OPC?
, and
*WAI
commands or queries the current setting.
5-15
:COMMunicate:OPSR?
Queries the operation pending status register.
5-15
:COMMunicate:OVERlap
Sets the commands that will operate as overlap commands or queries the
current setting.
5-15
:COMMunicate:REMote
Sets remote or local.
5-15
:COMMunicate:STATus?
Queries line-specific status.
5-15
:COMMunicate:VERBose
Sets the response messages to full form or abbreviated form or queries the
current setting.
5-15
:COMMunicate:WAIT
Waits for a specified extended event.
5-15
:COMMunicate:WAIT?
Creates the response that is returned when the specified event occurs.
5-16
CURSor Group
:CURSor?
Queries all settings related to the cursor measurement.
5-18
:CURSor:BAR?
Queries all settings related to the cursor measurement on the bar graph.
5-18
:CURSor:BAR:POSition<x>
Sets the cursor position (order) on the bar graph or queries the current
setting.
5-18
:CURSor:BAR[:STATe]
Turns ON/OFF the cursor display on the bar graph or queries the current
setting.
5-18
:CURSor:BAR:{Y<x>|DY}?
Queries the cursor measurement value on the bar graph.
5-18
:CURSor:TRENd?
Queries all settings related to the cursor measurement on the trend.
5-18
:CURSor:TRENd:POSition<x>
Sets the cursor position on the trend or queries the current setting.
5-18
:CURSor:TRENd[:STATe]
Turns ON/OFF the cursor display on the trend or queries the current setting. 5-19
:CURSor:TRENd:TRACe<x>
Sets the cursor target on the trend or queries the current setting.
5-19
:CURSor:TRENd:{X<x>|Y<x>|DY}?
Queries the cursor measurement value on the trend.
5-19
:CURSor:WAVE?
Queries all settings related to the cursor measurement on the waveform
display.
5-19
:CURSor:WAVE:PATH
Sets the cursor path on the waveform display or queries the current setting.
5-19
:CURSor:WAVE:POSition<x>
Sets the cursor position on the waveform display or queries the current
setting.
5-19
:CURSor:WAVE[:STATe]
Turns ON/OFF the cursor display on the waveform display or queries the
current setting.
5-19
:CURSor:WAVE:TRACe<x>
Sets the cursor target on the waveform display or queries the current setting. 5-19
:CURSor:WAVE:{X<x>|DX|PERDt|Y<x>|DY}?
Queries the cursor measurement value on the waveform display.
5-19
Chapter 5 Commands
Содержание wt1600
Страница 1: ...Digital Power Meter Communication Interface IM 760101 11E 4th Edition ...
Страница 131: ...7 2 IM 760101 11E 7 2 Sample Program Image ...
Страница 138: ...Sample Program 7 9 IM 760101 11E 7 7 4 Output of Normal Measurement Data ...
Страница 142: ...Sample Program 7 13 IM 760101 11E 7 7 5 Output of Harmonic Measurement Data ...