5-2
IM 760101-11E
Command
Function
Page
DISPlay Group
:DISPlay?
Queries all settings related to the screen display.
5-23
:DISPlay:BAR?
Queries all settings related to the bar graph.
5-23
:DISPlay:BAR:FORMat
Sets the display format of the bar graph or queries the current setting.
5-23
:DISPlay:BAR:ITEM<x>
Sets the bar graph item (function and element) or queries the current setting. 5-23
:DISPlay:BAR:ORDer
Sets the start and end orders of the bar graph or queries the current setting. 5-23
:DISPlay:FORMat
Sets the display format or queries the current setting.
5-23
:DISPlay:NUMeric?
Queries all settings related to the numerical display.
5-23
:DISPlay[:NUMeric]:HARMonics?
Queries all settings related to the numerical display for harmonic
measurement.
5-24
:DISPlay[:NUMeric]:HARMonics:IAMount
Sets the numerical display format for harmonic measurement or queries the
current setting.
5-24
:DISPlay[:NUMeric]:HARMonics:ICURsor
Sets the cursor position on the numerical display for harmonic measurement
or queries the current setting.
5-24
:DISPlay[:NUMeric]:HARMonics:ITEM<x>
Sets the numerical display item for harmonic measurement or queries the
current setting.
5-24
:DISPlay[:NUMeric]:HARMonics:LCURsor
Sets the cursor position on the list display for harmonic measurement or
queries the current setting.
5-25
:DISPlay[:NUMeric]:HARMonics:LIST<x>
Sets the list display item for harmonic measurement or queries the current
setting.
5-25
:DISPlay[:NUMeric]:HARMonics:PRESet
Presets the display order pattern of numerical display items for harmonic
measurement.
5-25
:DISPlay[:NUMeric]:NORMal?
Queries all settings related to the numerical display for normal measurement. 5-25
:DISPlay[:NUMeric]:NORMal:FCURsor
Sets the cursor position on the numerical display (all display) for normal
measurement or queries the current setting.
5-25
:DISPlay[:NUMeric]:NORMal:IAMount
Sets the numerical display format for normal measurement or queries the
current setting.
5-26
:DISPlay[:NUMeric]:NORMal:ICURsor
Sets the cursor position on the numerical display (split display) for normal
measurement or queries the current setting.
5-26
:DISPlay[:NUMeric]:NORMal:ITEM<x>
Sets the numerical display item for normal measurement or queries the
current setting.
5-26
:DISPlay[:NUMeric]:NORMal:PRESet
Presets the display order pattern of numerical display items for normal
measurement.
5-26
:DISPlay:TRENd?
Queries all settings related to the trend.
5-26
:DISPlay:TRENd:ALL
Collectively turns ON/OFF all trends.
5-27
:DISPlay:TRENd:FORMat
Sets the display format of the trend or queries the current setting.
5-27
:DISPlay:TRENd:HARMonics?
Queries all settings related to all the trends for harmonic measurement.
5-27
:DISPlay:TRENd:HARMonics:ITEM<x>?
Queries all settings related to the trend for harmonic measurement.
5-27
:DISPlay:TRENd:HARMonics:ITEM<x>[:FUNCtion]
Sets the trend item for harmonic measurement or queries the current setting. 5-27
:DISPlay:TRENd:HARMonics:ITEM<x>:SCALing?
Queries all settings related to the scaling of the trend for harmonic
measurement.
5-27
:DISPlay:TRENd:HARMonics:ITEM<x>:SCALing:MODE
Sets the scaling mode of the trend for harmonic measurement or queries the
current setting.
5-27
:DISPlay:TRENd:HARMonics:ITEM<x>:SCALing:VALue
Sets the upper and lower limits of manual scaling of the trend for harmonic
measurement or queries the current setting.
5-28
:DISPlay:TRENd:NORMal?
Queries all settings related to all the trends for normal measurement.
5-28
5.1 Command List
Содержание wt1600
Страница 1: ...Digital Power Meter Communication Interface IM 760101 11E 4th Edition ...
Страница 131: ...7 2 IM 760101 11E 7 2 Sample Program Image ...
Страница 138: ...Sample Program 7 9 IM 760101 11E 7 7 4 Output of Normal Measurement Data ...
Страница 142: ...Sample Program 7 13 IM 760101 11E 7 7 5 Output of Harmonic Measurement Data ...